Biomedical Engineering Reference
In-Depth Information
research interest. Although DLC and heparin coatings are utilized for some of
the third generation commercial cardiac devices due to their excellent haemo-
compatibility, bioactive coatings on blood-contacting surfaces have been a topic
of intense research.
Endothelial cell (EC) lining on biomaterials is suggested for long-term
cardiac devices due to its antithrombotic properties (Scott-Burden et al., 1998).
A few attempts on the use of an EC lining to enhance the blood compatibility
can be seen in the literature (Wang et al., 2002; Sreerekha and Krishnan, 2006).
EC lining can be created on different materials with textured surface using in
vitro cell culture. Even though biological surface coatings seem to be promising
as a future technology compared with the current technology, they need further
development and investigation due to their possible lasting limitations.
8.8 References
Alanazi, A., Nojiri, C., Noguchi, T., Kido, T., Komatsu, Y., Hirakuri, K., Funakubo, A.,
Sakai, K. & Fukui, Y. (2000) Improved blood compatibility of DLC coated
polymeric material. ASAIO Journal, 46, 440±443.
Anderson, J. M. (2006) Fundamental biological requirements of a biomaterial. In
Guelcher, S. A. & Hollinger, J. O. (Eds) An Introduction to Biomaterials. Boca
Raton, FL, Taylor & Francis Group.
Bernhard, W. F., Lafarge, C. G., Robinson, T., Yun, I., Shirahige, K. & Kitrilakis, S.
(1968) An improved blood±pump interface for left-ventricular bypass. Annals of
Surgery, 168, 750±763.
Biehl, V., Wack, T., Winter, S., Seyfert, U. T. & Breme, J. (2002) Evaluation of the
haemocompatibility of titanium based biomaterials. Biomolecular Engineering, 19,
97±101.
Brunski, J. B. (2004) Metals. In Ratner, B. D., Hoffman, A. S., Schoen, F. J. & Lemons, J.
E. (Eds) Biomaterials Science: An Introduction to Materials in Medicine, 2nd edn.
London, Elsevier.
Christel, P. S. (1992) Biocompatibility of surgical-grade dense polycrystalline alumina.
Clinical Orthopaedics & Related Research, 282, 10±18.
Christensen, K., Larsson, R., Emanuelsson, H., Elgue, G. & Larsson, A. (2001) Heparin
coating of the stent graft ± effects on platelets, coagulation and complement
activation. Biomaterials, 22, 349±355.
Curtis, J. J., Walls, J. T., Wagner-Mann, C. C., Schmaltz, R. A., Demmy, T. L.,
McKenney, C. A. & Mann, F. A. (1999) Centrifugal pumps: description of devices
and surgical techniques. Annals of Thoracic Surgery, 68, 666±671.
Dasse, K. A., Chipman, S. D., Sherman, C. N., Levine, A. H. & Frazier, O. H. (1987)
Clinical experience with textured blood contacting surfaces in ventricular assist
devices. ASAIO Journal, 33, 418±425.
Dearnaley, G. & Arps, J. H. (2005) Biomedical applications of diamond-like carbon
(DLC) coatings: a review. Surface and Coatings Technology, 200, 2518±2524.
Dion, I., Baquey, C., Candelon, B. & MontiÁs, J. R. (1992) Hemocompatibility of
titanium nitride. Biomaterials, 15, 617±621.
Dion, I., Baquey, C., MontiÁs, J. R. & Havlik, P. (1993a) Haemocompatibility of
Ti6Al4V alloy. Biomaterials, 14, 122±126.
￿ ￿ ￿ ￿ ￿