Biology Reference
In-Depth Information
Modulated laser source
Signal generator
Rotation axe
Microlenses disk
Pinhole disk
Figure 5.15 Scheme of a phase and modulation acquisition system adapted on a spin-
ning disk system to ensure fast fluorescence lifetime measurement with optical section-
ing capability.
I
FRET
a
I
Donor
b
I
Acceptor
R
¼
½
5
:
27
I
Donor
where
I
Acceptor
is the fluorescence intensity measured with an acceptor emis-
sion filter after acceptor excitation,
I
Donor
and
I
FRET
are fluorescence inten-
sities measured, respectively, with the spectral bandpass of the donor and
acceptor after donor excitation, and a and b are the correction factors
for, respectively, the bleed-through of the donor into the acceptor emission
filter after donor excitation and the bleed-through of the acceptor into the
acceptor emission filter after donor excitation.
In the particular case of a single-chain biosensor, the expression (27) can
be simplified. Indeed, donor and acceptor concentrations are identical,
which implies that bleed-through correction factors a and b are linearly de-
pendent and that fluorescence intensities
I
Acceptor
and
I
Donor
are propor-
tional. Taking into account
these simplifications, a straightforward
calculation leads to
I
FRET
R
¼
I
Donor
c
½
5
:
28