Biomedical Engineering Reference
In-Depth Information
236. Kuralay, F., Ö Zyörük, H., and Yıldız, A., Amperometric enzyme electrode for urea determination using
immobilized urease in poly(vinylferrocene) fi lm, Sensor. Actuator. B Chem. , 114, 500-506, 2006.
237. Dicks, J.M. et al., The application of ferrocene-modifi ed n-type silicon in glucose biosensors, Electro-
analysis , 5, 1, 1993.
238. Mu, S.L. and Xue, H.G., Bioelectrochemical characteristics of glucose oxidase immobilized in a poly-
aniline fi lm, Sensor. Actuator. B Chem. , 31, 155, 1996.
239. Vidal, J.C. et al., Recent advances in electropolymerized conducting polymers in amperometric biosen-
sors, Mikrochim. Acta , 143, 93, 2003.
240. Schuhmann, W. et al., Polypyrrole, a new possibility for covalent binding of oxidoreductases to elec-
trode surfaces as a base for stable biosensors, Sensor. Actuator. B Chem. , 1, 537, 1990.
241. Calvo-Muñoz, M.L. et al., Electrochemical study by a redox probe of the chemical post-functionaliza-
tion of N-substituted polypyrrole fi lms: application of a new approach to immobilization of biotinylated
molecules, J. Electroanal. Chem. , 578, 301, 2005.
242. Hiller, M. et al., Amperometric biosensors produced by immobilization of redox enzymes at polythio-
phene-modifi ed electrode surfaces, Adv. Mater. , 8, 219, 1996.
243. Porath, J. et al., Metal chelate affi nity chromatography, a new approach to protein fractionation, Nature ,
258, 598, 1997.
244. Davis, J. et al., Spectroscopic evaluation of protein affi nity binding at polymeric biosensor fi lms, J. Am.
Chem. Soc. , 121, 4302, 1999.
245. Halliwell, M.C. et al., Immobilisation of lactate dehydrogenase on poly (aniline)-poly (acrylate) and
poly (aniline)-poly (vinyl sulphonate) fi lms for use in a lactate biosensor, Anal. Chim. Acta , 453, 191,
2002.
246. Halliwell, M.C. et al., The design of dehydrogenase enzymes for use in a biofuel cell: the role of genetically
introduced peptide tags in enzyme immobilization on electrodes, Bioelectrochemistry , 55, 21, 2002.
247. Pantano, P., Morton, T.H., and Kuhr, W.G., Enzyme-modifi ed carbon-fi ber microelectrodes with mil-
lisecond response times, J. Am. Chem. Soc ., 113, 1832, 1991.
248. Cosnier, S. et al., Electrogeneration of biotinylated functionalized polypyrroles for the simple immobi-
lization of enzymes, Electroanalysis , 10, 808, 1998.
249. Cosnier, S. et al., A biotinylated conducting polypyrrole for the spatially controlled construction of an
amperometric biosensor, Anal . Chem. , 71, 3692, 1999.
250. Livache, T. et al., Electroconducting polymers for the construction of DNA or peptide arrays on silicon
chips, Biosens. Bioelectron ., 13, 629, 1998.
251. Da Silva, S. et al., Biotinylated polypyrrole fi lms: an easy electrochemical approach for the reagentless
immobilization of bacteria on electrode surfaces, Bioelectrochemistry , 63, 297, 2004.
252. Zhou, H.H. et al., Glucose biosensor based on platinum microparticles dispersed in nano-fi brous poly-
aniline, Biosens. Bioelectron ., 20, 1305, 2005.
253. Parthasarathy, R.V. and Martin, C.R., Enzyme and chemical encapsulation in polymeric microcapsules,
J. Appl. Polym. Sci. , 62, 875, 1996.
254. Parthasarathy, R.V. and Martin, C.R., Synthesis of polymeric microcapsule arrays and their use for
enzyme immobilization, Nature , 369, 298, 1994.
255. Martin, C.R., Nanomaterials: a membrane-based synthetic approach, Science , 266, 1961, 1994.
256. Jongseo, P., Jungsuk, K., and Yongkeun, S., Conducting polymer micro-tubules hosting electroactive
species without guest modifi cation, Synthetic Met ., 156, 714, 2006.
257. Miao, Y.Q., Chen, J.R., and Wu, X.H., Using electropolymerized non-conducting polymers to develop
enzyme amperometric biosensors, Tren ds Biotech nol ., 22, 227, 2004.
258. Nakabayshi, Y. et al., Amperometric glucose sensors fabricated by electrochemical polymerization of
phenols on carbon paste electrodes containing ferrocene as electron transfer mediator, Anal. Sci ., 14,
1069, 1997.
259. Nakabayashi, Y. and Yoshikawa, H., Amperometric biosensors for sensing of hydrogen peroxide based on
electron transfer between horseradish peroxidase and ferrocene as a mediator, Anal. Sci ., 16, 609, 2000.
260. Bartlett, P.N. and Caruana, D.J., Electrochemical immobilization of enzymes. Part V. Microelectrodes
for the detection of glucose based on glucose oxidase immobilized in a poly(phend) fi lm, Analyst , 117,
1287, 1992.
261. Yang, Q.L., Atanasov, P., and Wilkins, E., Development of needle-type glucose sensor with high selec-
tivity, Sensor. Actuator. B Chem. , 46, 249, 1992.
262. Murphy, L.J., Reduction of interference response at a hydrogen peroxide detecting electrode using
electropolymerized fi lms of substituted naphthalenes, Anal. Chem ., 70, 2928, 1998.
Search WWH ::




Custom Search