Biomedical Engineering Reference
In-Depth Information
119. Yang, Z. et al., Fabrication of oxygen electrode arrays and their incorporation into sensors for measuring
biochemical oxygen demand, Anal. Chim. Acta , 357, 41, 1997.
120. Yano, Y. et al., Application of a microbial sensor to the quality control of meat freshness, Talanta , 54,
255, 2001.
121. Lehmann, M. et al., Amperometric measurement of copper ions with a deputy substrate using a novel
Saccharomyces cerevisiae sensor, Biosens. Bioelectron. , 15, 211, 2000.
122. Zyracka, E. et al., Yeast as a biosensor for antioxidants: simple growth tests employing a Saccharomyces
cerevisiae mutant defective in superoxide dismutase, Acta. Biochim. Pol. , 52, 679, 2005.
123. Middelhoven, W.J., De Jong, I.M., and De Winter, M., Arxula adeninivorans , a yeast assimilating many
nitrogenous and aromatic compounds, Anton. Leeuw. Int. J. G. , 59, 129, 1991.
124. Riedel, K. et al., Arxula adeninivorans based sensor for the estimation of BOD, Anal. Lett. , 31, 1, 1998.
125. Chan, C.Y. et al., Measurement of biodegradable substances using the salt-tolerant yeast Arxula adenini-
vorans for a microbial sensor immobilized with poly(carbamoyl) sulfonate (PCS) part I: construction
and characterization of the microbial sensor, Biosens. Bioelectron. , 14, 131, 1999.
126. Lehmann, M. et al., Measurement of biodegradable substances using the salt-tolerant yeast Arxula ade-
ninivorans for a microbial sensor immobilized with poly(carbamoyl)sulfonate (PCS)—part II: applica-
tion of the novel biosensor to real samples from coastal and island regions, Biosens. Bioelectron. , 14,
295, 1999.
127. Sugandhi, G. et al., Torulopsis candida based sensor for the estimation of biochemical oxygen demand
and its evaluation, Electroanalysis , 8, 698, 1996.
128. Reshetilov, A.N. et al., Characteristics of Gluconobacter oxydans B-1280 and pichia methanolica MN4
cell based biosensors for detection of ethanol, Process Biochem. , 36, 1015, 2001.
129. http://ghr.nlm.nih.gov/handbook/basics/dna
130. Liu, A.H. and Anzai, J.I., Use of polymeric indicator for electrochemical DNA sensors: poly(4-vinylpyr-
idine) derivative bearing [Os(5,6-dimethyl-1,10-phenanthroline)2Cl] 2 + , Anal. Chem. , 76, 2975, 2004.
131. Wang, S.G. et al., DNA biosensors based on self-assembled carbon nanotubes, Biochem. Bioph. Res.
Commun. , 325, 1433, 2004.
132. Watts, H.J., Yeung, D., and Parkes, H., Real-time detection and quantifi cation of DNA hybridization by
an optical biosensor, Anal. Chem. , 67, 4283, 1995.
133. Zhang, H. et al., Bovine serum albumin as a means to immobilize DNA on a silver-plated bulk acoustic
wave DNA biosensor, Talanta , 46, 171, 1998.
134. Lazerges, M. et al., In situ QCM DNA-biosensor probe modifi cation, Sensor. Actuator. B.Chem. , 120,
329, 2006.
135. Brett, A.M.O. et al., Voltammetric behaviour of mitoxantrone at a DNA-biosensor, Biosens. Bioelec-
tron. , 13, 861, 1998.
136. Chiti, G., Marrazza, G., and Mascini, M., Electrochemical DNA biosensor for environmental monitor-
ing, Anal. Chim. Acta , 427, 155, 2001.
137. Kerman, K. et al., Electrochemical DNA biosensor for the determination of benzo[a] pyrene-DNA
adducts, Anal. Chim. Acta , 450, 45, 2001.
138. Breimer, M.A., Gelfand, Y., and Sadik, O.A., Integrated capillary fl uorescence DNA biosensor, Bio-
sens. Bioelectron. , 18, 1135, 2003.
139. Babkina, S.S., Ulakhovich, N.A., and Zyavkina, Y.I., Amperometric DNA biosensor for the determina-
tion of auto-antibodies using DNA interaction with pt(II) complex, Anal. Chim. Acta , 502, 23, 2004.
140. Guilbault, G.G., Hock, B., and Schimid, R., A piezoelectric immunobiosensor for atrazine in drinking
water, Biosens. Bioelectron. , 7, 411, 1992.
141. Suri, C.R., Rajem, M., and Mishra, G.C., Determination of immunoglobulin M concentration by piezo-
electric crystal immunobiosensor coated with protamine, Biosens. Bioelectron. , 9, 535, 1994.
142. Tsai, W.C. and Lin, I.C., Development of a piezoelectric immunosensor for the detection of alpha-feto-
protein, Sensor. Actuator. B Chem. , 106, 455, 2005.
143. Gao, H. et al., Electrochemical immunoassay of estrone at an antibody-modifi ed conducting polymer
electrode towards immunobiosensors, J. Electroanal. Chem. , 592, 88, 2006.
144. Messina, G.A. et al., Continuous-fl ow/stopped-fl ow system using an immunobiosensor for quantifi ca-
tion of human serum IgG antibodies to Helicobacter pylori , Anal. Biochem. , 337, 195, 2005.
145. Wu, J. et al., A disposable electrochemical immunosensor for fl ow injection immunoassay of carcino-
embryonic antigen, Biosens. Bioelectron. , 22, 102, 2006.
146. Elliott, C.T. et al., The development of a rapid immunobiosensor screening method for the detection of
residues of sulphadiazine, Food Agr. Immunol. , 11, 19, 1999.
Search WWH ::




Custom Search