Information Technology Reference
In-Depth Information
Low-level software—default condition requirements
Communication protocols and diagnostics
Module connector type and pins requirements (h/w)
Control voltage wiring harness requirements—type, length, routing, protec-
tion, insulation, EMC—grounding and shielding (h/w & vehicle)
Sensor interface wiring harness requirements—type, length, routing, protec-
tion, insulation, EMC—grounding and shielding (h/w & vehicle)
3. Alternative Energy Control Unit (in scope)
Sensor interfaces of alternative energy source—This section details require-
ment related to interfacing of low-voltage sensor, high-voltage sensor, al-
ternative energy source temperature sensor, ambient air temperature sensor,
cooling system temperature sensor, explosive gas detection sensor, local
temperature sensor for alternative energy source, and current sensor with
electronic control unit.
Low-Voltage Sensor—type, operating range, resolution, supply voltages,
number of sensors required, interface, placement, environment operating
temperature range, and enclosure requirements
High-Voltage Sensor—type, operating range, resolution, supply voltages,
number of sensors required, interface, placement, environment operating
temperature range, and enclosure requirements
Current Sensor—type, operating range, resolution, supply voltages, num-
ber of sensors required, interface, placement, environment operating tem-
perature range, and enclosure requirements
Ambient Air Temperature Sensor—type, operating range, resolution, sup-
ply voltages, number of sensors required, interface, placement, environ-
ment operating temperature range, and enclosure requirements
Alternative Energy Source Temperature Sensor(s)—type, operating range,
resolution, supply voltages, number of sensors required, interface, place-
ment, environment operating temperature range, and enclosure require-
ments
Local Temperature Sensor(s) for Alternative Energy Source—type, oper-
ating range, resolution, supply voltages, number of sensors required, inter-
face, placement, environment operating temperature range, and enclosure
requirements
Cooling System Temperature Sensor—type, operating range, resolution,
supply voltages, number of sensors required, interface, placement, envi-
ronment operating temperature range, and enclosure requirements
Explosive Gas Detection Sensor—type, operating range, resolution, supply
voltages, number of sensors required, interface, placement, environment
operating temperature range, and enclosure requirements
Redundant sensing—part of scope