Biomedical Engineering Reference
In-Depth Information
[112] Herminghaus, S.; Fery, A.; Reim, D., Imaging of droplets of aqueous solutions by tapping-
mode scanning force microscopy. Ultramicroscopy 1997, 69 (3), 211-17.
[113] Checco, A.; Schollmeyer, H.; Daillant, J.; Guenoun, P.; Boukherroub, R., Nanoscale wett-
ability of self-assembled monolayers investigated by noncontact atomic force microscopy.
Langmuir 2006, 22 (1), 116-26.
[114] Yang, C.-W.; Hwang, I.-S.; Chen, Y. F.; Chang, C. S.; Tsai, D. P., Imaging of soft matter with
tapping-mode atomic force microscopy and non-contact-mode atomic force microscopy.
Nanotechnology 2007, 18 (8), 084009.
[115] Hoogenboom, B. W.; Hug, H. J.; Pellmont, Y.; Martin, S.; Frederix, P. L. T. M.; Fotiadis, D.;
Engel, A., Quantitative dynamic-mode scanning force microscopy in liquid. Applied Physics
Letters 2006, 88 (19), 193109-3.
[116] Zimmermann, H.; Hagedorn, R.; Richter, E.; Fuhr, G., Topography of cell traces studied by
atomic force microscopy. European Biophysics Journal 1999, 28 (6), 516-25.
[117] Albrecht, T. R.; Grutter, P.; Horne, D.; Rugar, D., Frequency modulation detection using high-
Q cantilevers for enhanced force microscope sensitivity. Journal of Applied Physics 1991, 69
(2), 668-73.
[118] Sugawara, Y.; Ohta, M.; Ueyama, H.; Morita, S., Defect motion on an InP(110) surface
observed with noncontact atomic force microscopy. Science 1995, 270 (5242), 1646-48.
[119] Luthi, R.; Meyer, E.; Bammerlin, M.; Baratoff, A.; Lehmann, T.; Howald, L.; Gerber, C.;
Guntherodt, H. J., Atomic resolution in dynamic force microscopy across steps on Si(111)
7
7. Zeitschrift Fur Physik B - Condensed Matter 1996, 100 (2), 165-67.
[120] Sugimoto, Y.; Abe, M.; Konoshita, S.; Morita, S., Direct observation of the vacancy site of the
iron silicide c(4 8) phase using frequency modulation atomic force microscopy. Nano-
technology 2007, 18 (8), 084012.
[121] Seino, Y.; Yoshikawa, S.; Abe, M.; Morita, S., Growth dynamics of insulating SrF2 films on
Si(111). Journal of Physics - Condensed Matter 2007, 19 (44), 9.
[122] Sugimoto, Y.; Abe, M.; Hirayama, S.; Morita, S., Highly resolved non-contact atomic force
microscopy images of the Sn/Si(111)-(2 root 3 2 root 3) surface. Nanotechnology 2006, 17
(16), 4235-39.
[123] Eaton, P.; Ragusa, A.; Clavel, C.; Rojas, C. T.; Graham, P.; Duran, R. V.; Penades, S.,
Glyconanoparticle-DNA interactions: an atomic force microscopy study. IEEE Transactions
on Nanobioscience 2007, 6 (4), 309-18.
[124] Han, W.; Lindsay, S. M.; Jing, T., A magnetically driven oscillating probe microscope for
operation in liquids. Applied Physics Letters 1996, 69 (26), 4111-13.
[125] Revenko, I.; Proksch, R., Magnetic and acoustic tapping mode microscopy of liquid
phase phospholipid bilayers and DNA molecules. Journal of Applied Physics 2000, 87
(1), 526-33.
[126] Putman, C. A. J.; Van der Werf, K. O.; De Grooth, B. G.; Van Hulst, N. F.; Greve, J.,
Tapping mode atomic force microscopy in liquid. Applied Physics Letters 1994, 64 (18),
2454-56.
[127] Volkov, A. O.; Burnell-Gray, J. S.; Datta, P. K., Frequency response of atomic force
microscope cantilever driven by fluid. Applied Physics Letters 2004, 85 (22), 5397-99.
[128] Sch¨ffer, T. E.; Cleveland, J. P.; Ohnesorge, F.; Walters, D. A.; Hansma, P. K., Studies of
vibrating atomic force microscope cantilevers in liquid. Journal of Applied Physics 1996, 80
(7), 3622-7.
[129] Connell, S. D.; Smith, D. A., The atomic force microscope as a tool for studying phase
separation in lipid membranes (review). Molecular Membrane Biology 2006, 23 (1), 17-28.
[130] Lantz, M.; Liu, Y. Z.; Cui, X. D.; Tokumoto, H.; Lindsay, S. M. Dynamic force microscopy in
fluid , 3rd Conference on Development and Industrial Application of Scanning Probe Methods
(SXM-3), Switzerland, John Wiley, 1998; pp 354-60.
Search WWH ::