Civil Engineering Reference
In-Depth Information
β
Figure 6.10
Function of deviation angle, f
3
(
)
/
f
c
(
MPa
) is greater than 0.9. The
constant of 0.9 governs
and Eq. (
6.51) degenerates into Eq. (6.50). When
f
c
is greater than
42 MPa, however, 5
When concrete strength
f
c
is less than 42 MPa, 5
.
8
/
f
c
(
MPa
) is less than 0.9 and this term will dominate.
calculated by
Equation (6.51) will be less than that calculated by Equation (6.50). Equation (6.51) provides
a simple concept: the higher the concrete strength
f
c
, the lower the softened coefficient
.
8
ζ
ζ
.
6.1.7.3 Function of Deviation Angle
f
3
(
β
)
In the fixed angle theory, the softening coefficient
ζ
is also a function of the deviation angle
β
,
ε
1
and
f
c
. The angle
in addition to the variables
β
is defined as:
β
=
α
1
−
α
r
, the difference
between the angle
α
1
of the applied principal stresses in the 1-2 coordinate and the angle
α
r
of
the principal concrete stresses in the
r
−
d
coordinate. Angle
β
has been discussed in Sections
4.3.1 and 4.3.5, and in Figure 4.14.
Figure 6.10 shows that
f
3
(
β
) is a linear function of the deviation angle
β
, and can be
24
◦
. This straight-line expression was
determined by regression analysis (Wang, 2006) based on three sets of test data:
expressed by a simple formula,
f
3
(
β
)
=
1
− |
β
|
/
1. Pang and Hsu (1995) tested ten panels (A series and B series) made of normal-strength
concrete of approximately 42 MPa and reinforced with steel percentages from 0.6 to 3.0%
in the longitudinal and transverse directions. The ratio
ρ
/ρ
t
ranged from 1 to 5.
2. Zhang and Hsu (1998) tested nine panels (VA series and VB series) made of high-strength
concrete of approximately 100 MPa, and reinforced with steel percentages in the range
0.42-6.0%. The ratio
ρ
/ρ
t
also varied from 1 to 5.
3. Chintrakarn (2001) tested six panels (M series) with concrete strength of approximately
45 MPa. The ratios
ρ
/ρ
t
in panels M1-M6 were much larger than those tested by Pang
and Hsu (1995) and Zhang and Hsu (1998). The four panels M2, M3, M4 and M5 had
ρ
/ρ
t
ratios of 4.0, 9.0, 7.2, and 15.6, respectively. No steel was placed in the transverse
direction in panels M1 and M6, giving a
ρ
/ρ
t
ratio of infinity.
0. When a
2-D shear element is reinforced with the same amounts of steel bars in the two directions
The straight-line function
f
3
(
β
) has an intercept of
f
3
(
β
)
=
1, when
β
=