Digital Signal Processing Reference
In-Depth Information
Fig. 31.13. Olympic Tower Munich; antenna installation for DVB-T using a heli-
copter (left) and Wendelstein antenna (right)
Table 31.4. Technical parameters Olympic Tower transmitter
Channel
Frequency
Average
transmitter
output
power
ERP
10
212.5 MHz
7.2 kW
20 kW
omnidir.
34
578 MHz
9.3 kW
100 kW
omnidir.
35
586 MHz
9.3 kW
100 kW
omnidir.
48
690 MHz
9.3 kW
100 kW
omnidir.
56
754 MHz
9.3 kW
100 kW
omnidir.
66
834 MHz
9.3 kW
100 kW
omnidir.
The high-power transmitters are also liquid-cooled NV/NM7000 series
solidstate transmitters by Rohde&Schwarz, but with much higher power