Digital Signal Processing Reference
In-Depth Information
c fu = 20 log(U peak /U RMS );
Power meters and spectrum analyzers are sometimes also calibrated to
the following definition:
c fp = 10 log(PEP)/P AVG ;
where PEP is the peak envelope power (U peak /√2) 2 / z o ;
and P AVG = U RMS 2 / z o ;
The two crest factor definitions thus differ by 3 dB:
c fu = c fp .+ 3 dB;
The crest factor of COFDM signals is calculated as follows:
The maximum peak voltage is obtained by adding together the peak
amplitudes of all single carriers:
peak = N • U peak0 ;
where U peak0 is the peak amplitude of a single COFDM carrier
and N is the number of COFDM carriers used.
The RMS value of a COFDM signal is calculated from the quadratic
mean as:
2
U
=
N
U
;
RMS
RMS
0
where U RMS is the RMS voltage of a single COFDM carrier
2
U
peak
0
U
=
;
RMS
0
2
The RMS value of the COFDM signal is then:
2
U
peak
0
U
=
N
;
RMS
2
Search WWH ::