Digital Signal Processing Reference
In-Depth Information
c
fu
= 20 log(U
peak
/U
RMS
);
Power meters and spectrum analyzers are sometimes also calibrated to
the following definition:
c
fp
= 10 log(PEP)/P
AVG
;
where PEP is the peak envelope power (U
peak
/√2)
2
/ z
o
;
and P
AVG
= U
RMS
2
/ z
o
;
The two crest factor definitions thus differ by 3 dB:
c
fu
= c
fp
.+ 3 dB;
The crest factor of COFDM signals is calculated as follows:
The maximum peak voltage is obtained by adding together the peak
amplitudes of all single carriers:
peak
= N • U
peak0
;
where U
peak0
is the peak amplitude of a single COFDM carrier
and N is the number of COFDM carriers used.
The RMS value of a COFDM signal is calculated from the quadratic
mean as:
2
U
=
N
⋅
U
;
RMS
RMS
0
where
U
RMS
is the RMS voltage of a single COFDM carrier
2
U
peak
0
U
=
;
RMS
0
2
The RMS value of the COFDM signal is then:
2
U
peak
0
U
=
N
⋅
;
RMS
2
Search WWH ::