2.
Disturb coupling fault
(
CF
ds
): an operation (write or read) performed on the
aggressor cell forces the victim cell into a given logic state. Any oper-
ation performed on the aggressor is accepted as sensitizing operation (a
read, a transition write, or a non-transition write). Twelve types of disturb
coupling faults exist, defined as
CF
ds
.x
z
;
w
y
/
D
˚
<x
a
z
v
;
w
y
=
z
v
=
>
,and
CF
ds
.x
z
;r
y
/
D
f
<x
a
y
v
;r
x
= y
v
=
>
g
where x; y;
z
2
f
0; 1
g
. This covers FP
5
,
FP
6
,FP
7
,FP
8
,FP
9
,FP
10
,FP
11
,FP
12
,FP
13
,FP
14
,FP
15
,andFP
16
.
3.
Transition coupling fault
(
CF
tr
): the state of the aggressor cell causes the fail-
ure of a transition write operation performed on the victim cell. This fault is
sensitized by a write operation on the victim cell, while the aggressor is in a
given state. Four types of transition coupling faults exist, defined as
CF
tr.x0/
D
˚
<x
a
0;
w
1
=0
v
=
>
,and
CF
tr
.x1/
D
˚
<x
a
1;
w
0
=1
v
=
>
where x
2 f
0; 1
g
.
This covers FP
19
,FP
20
,FP
21
,FP
22
.
4.
Write destructive coupling fault
(
CF
wd
): a non-transition write operation per-
formed on the victim cell while the aggressor cell is in a given state results in a
transition of the cell itself. Four types of write destructive coupling faults exist,
defined as
CF
wd
.
xy
/
D
˚
<x
a
y
v
;
w
y
= y
v
=
>
,wherex; y
2 f
0; 1
g
. This covers
FP
17
,FP
18
,FP
23
,FP
24
.
5.
Read destructive coupling fault
(
CF
rd
): a read operation performed on the vic-
tim cell, while the aggressor cell is in a given state, destroys the data stored
in the victim. Four types of read destructive coupling faults exist, defined as
CF
rd
.
xy
/
D
˚
<x
a
y
v
;r
y
= y
v
= y
v
>
,wherex; y
2 f
0; 1
g
. This covers FP
29
,FP
30
,
FP
31
,FP
32
.
6.
Incorrect read coupling fault (CFir
): a read operation performed on the vic-
tim cell returns the incorrect logic value, while the aggressor is in a given
state. Four types of incorrect read coupling faults exist, defined as
CF
ir
.
xy
/
D
˚
<x
a
y
v
;r
y
=y
v
= y
v
>
,wherex; y
2 f
0; 1
g
. This covers FP
25
,FP
35
,FP
26
,
FP
36
.
7.
Deceptive read destructive coupling fault (CFdr)
: a read operation performed on
the victim cell returns the correct logic value and changes the contents of the
victim while the aggressor is in a given logic state. Four types of deceptive read
destructive coupling faults exist, defined as
CF
dr
.xy/
D
˚
<x
a
y
v
;r
y
= y
v
=y
v
>
,
where x; y
2 f
0; 1
g
.ThiscoversFP
27
,FP
33
,FP
28
,FP
34
.
test covering these FFMs is therefore able to cover all possible 2-coupling static
faults. Other sets of fault models have been presented in the literature, such as:
Idempotent coupling fault
(
CF
id
): a transition write operation on the aggressor
cell forces the victim in a given state:
CF
id
.xy;
w
x
/
D
˚
<x
a
y
v
;
w
a
x
= y
v
=
>
,
where x; y
2 f
0; 1
g
.
Inversion coupling fault
(
CF
in
): a transition write operation on the aggressor
cell flips the content of the victim cell:
CF
in
.x;
w
x
/
D
˚
<x
a
0
v
;
w
a
x
=1
v
=
> ,
x
=0
v
=
>
,wherex
2 f
0; 1
g
.
<x
a
1
v
;
w
a