Civil Engineering Reference
In-Depth Information
If the applied load is cyclical, fatigue must be considered. A connec-
tion such as that shown in Figure E9.5 has an allowable fatigue shear stress
range of 16 ksi for connections subjected to greater than 2 million stress
range cycles. The connection is, therefore, acceptable with respect to fatigue
considerations.
Example 9.7
Design the bolted beam framing connection using 6
×
6
×
1 / 2 in. angles
as shown in Figure E9.6 for a shear force, P
=
70 kips and end moment,
M e =
25 ft-kip. The beam is 20 ft long and frames into the web of a plate
girder with single-shear connections. The allowable shear stress on the
high-strength bolts is 17.0 ksi. The shear force and bending moment were
developed from an analysis considering partial rigidity of the connection, so
the AREMA recommendation of a 25% increase in shear force is not used.
P =
70 kips
M e =
25 ft-kips
=
300 in-kips in the direction creating tension at the top of
the beam end
Shear and Bending on Bolts in the End Section:
Bolt forces due to bending:
The centroid of the connection is
y
2 ( 12
+
9
+
6
+
3 )
6.0 in.
The section modulus of the top (third row) bolts in the connection is
=
=
10
6.0 ) 2
6.0 ) 2
6.0 ) 2
6.0 ) 2
6.0 ) 2 )
2 (( 12
+
( 9
+
( 6
+
( 3
+
( 0
S bt =
=
30.0 bolt-in for top
( 12
6.0 )
bolts (in tension in the simple beam connection)
The section modulus of the second row bolts in the connection is
S bb =
6.0 ) 2
6.0 ) 2
6.0 ) 2
6.0 ) 2
6.0 ) 2 )
2 (( 12
+
( 9
+
( 6
+
( 3
+
( 0
=
60.0 bolt-in for bot-
( 9
6.0 )
tom bolts
P
P /2
P /2
3", typ.
0.5"
0.5"
M e
15"
21"
y
2.5"
6"
2.5"
2.25"
Side elevation
End section
FIGURE E9.6
 
 