Civil Engineering Reference
In-Depth Information
For a CJP weld with backing bar removed, the weld size must be
0.5 2 ( 3.37 )/ 16
0.15 in. OK since the web thickness is 0.625 in.
In general, CJP weld design does not need to be considered.
Design of Web Plate Stiffeners:
Use angles bolted to the web in order to preclude fatigue issues related
to welding at the base of the transverse stiffeners.
The spacing of the stiffeners is
a 0 < h
=
85 in.
< 96 in.
1.95 t w E
τ
1.95 ( 0.625 ) 29,000
< a
486/53.13
68.6 in.
Use a stiffener spacing of ( 11.25 )( 12 )/ 2
=
67.5 in. (1/2 the distance between
brace frames)
h
a
0.7
2.5 ( 67.5 )( 0.625 ) 3 85
68.6
0.7
2
2
2.5 a 0 t w
34.4 in. 4 .
I ts =
=
=
1
As shown in Figure E7.2a, a single 6
×
4
×
2 angle on one side of the web plate
4.75 ( 1.99 ) 2
36.2 in. 4 .
provides I ts =
17.4
+
=
Design of Bearing Stiffeners :
As shown in Figure E7.2b, the bearing stiffeners are to consist of 4
L 8
×
1
4
×
2 .
30.50 in. 2 ,
A ebs =
2 A bs +
A wbs =
2 A bs +
12 t w =
2 ( 2 )( 5.75 ) +
12 ( 0.625 ) =
2 A bs y 2
t w =
2 ( 2 )( 5.75 )( 3.17 ) 2
+ ( 0.625 ) 4
I ebs =
2 I bs +
+
2 ( 2 )( 38.5 ) +
385.6 in. 4 ,
=
385.6
30.50 =
r ebs =
3.56 in.,
h
r ebs =
85
3.56 =
23.9,
0.839 E / F y =
20.2 and, therefore, the governing expression for allowable
compressive stress is Equation 7.74
17,500 F y
E
3 / 2 0.75 h
r ebs
F call =
0.60 F y
=
30
0.124 ( 17.9 ) =
27.8 ksi,
P call = ( 27.8 )( 30.50 ) =
847 kips > 486 kips OK.
The reduced bearing stiffener area assuming a 1/2 clip is made to clear
the fillet at the web-to-flange junction (from double bevel CJP groove welds),
A bs =
15.0 in. 2 .
2 ( 2 )( 8
0.50 )( 0.5 ) =
A bs ( 0.83 F y ) ( 15.0 )( 0.83 )( 50 )
R
=
486
622.5 kips OK
 
Search WWH ::




Custom Search