Detailed design of a tension flange :
I x n
c t
M t max
F all
M t max
0.55 F y
9814 ( 12 )
0.55 ( 50 )
4282 in. 3 ( OK, 4469 in. 3 provided )
S x n =
for Category B weld;
M max -range
F fat
( 6032 )( 12 )
16
4524 in. 3 ( OK,
S x n
1% overstress with
4469 in. 3 provided ) .
A subsequent check on the net section is required after the detailed design
is completed.
Detailed design of a compression flange :
Brace frames will be placed at equal intervals of 11.25 ft
5.55 E
L p
r c y =
11.25 ( 12 )
4.67
=
28.9
F y
134 OK,
( 11.25 )( 12 )
4.67
2
0.55 ( 50 ) 2
6.3
F call =
0.55 ( 50 )
=
27.5
0.64
=
26.9 ksi,
2 ( 29,000 )
π
or
π ( 29,000 )( 50.0 )
( 11.25 )( 12 )( 90 )( 1
0.13
F call =
=
42.8 ksi.
+
0.3 )
Since F call
0.55 F y
27.5; F call =
26.9 ksi
I x g
c c
9814 ( 12 )
26.9
M c max
F call
4378 in. 3 ( OK, 4965 in. 3 provided ) .
S x g =
Vertical buckling of the compression flange is avoided by precluding
flexural buckling of the web when
f c
F cr
0.18 ( 85 ) 50
29,000
0.18 h F y
E
9814 ( 12 ) /4965
26.9
0.64 23.7
26.9
t w
0.60 in. ( OK, 0.625 in. provided ) .
Local buckling of the compression flange :
The plate girder will have ties directly supported on the top (compression)
flange; therefore
0.35 E
b
2 t f =
20
2 ( 2.50 ) =
4.0
F y
8.4 OK
 