TABLE E7.1
Design Force
Shear Force, V (kips)
Bending Moment, M (ft-kips)
Dead load, DL
110
2500
Live load + 37% impact (maximum)
376
7314
Maximum (DL
+
LL)
486
9814
Live load + 13% impact (fatigue)
310
6032
Preliminary girder design :
Use a girder depth of 90 / 12
90 (see Chapter 3) and assume 2-1 / 2
thick flanges (reasonable practical thickness );
7.5 =
=
486
0.35 ( 50 )( 90
0.33 ,
t w
5 )
use 3/8” (a minimum of 0.335” as per AREMA, 2008).
However, a minimum web slenderness of 134 is recommended for 50 ksi
steel and t w
0.63 without longitudinal stiffeners (0.32 with
longitudinal stiffeners). Use a 5 / 8 thick web without longitudinal stiffen-
ers. The designer should confirm that a 5 / 8 thick plate is available with a
minimum width of 86 (allowing for trimming) in sufficient lengths to avoid
excessive or poorly located vertical web plate splices.
90
5 / 134
7314 ( 12 )
16 ( 90
53.1
6 =
55.7 in. 2
A f =
5 )
( f b =
16 ksi is the allowable stress for fatigue Category B with no welded
attachments, which means that, if transverse web stiffeners are required, a
bolted connection to the web will be necessary)
9814 ( 12 )
0.55 ( 50 )( 90
53.1
6 =
41.5 in. 2
A f =
5 )
( f b =
27.5 ksi is the allowable bending stress).
Use 2-1 / 2 ×
50.0 in. 2 ) ; the designer should confirm that a 2-1 / 2
thickplateisavailableinsufficientlengthstoavoidexcessiveorpoorlylocated
transverse flange plate splices.
The girder section properties are shown in Figure E7.1 and Table E7.2.
20 ( A f =
Ay b
A
6890.6
153.13 =
=
45.00 in.,
This is a reasonable plate thickness from an economic and technical (lamellar tearing, grain size)
perspective.
 
 