Biomedical Engineering Reference
In-Depth Information
41. Labbé, C., Froment, J.C., Kennedy, A., Ashburner, J., and Cinotto, L., Positron
emission tomography metabolic data correction for cortical atrophy using
magnetic resonance imaging.
Alzheimer. Dis. & Assoc. Disord
. 1996; 10:141-170.
42. Rousset, O.G., Ma, Y., and Evans, A.C. Correction for partial volume effects in
PET: principle and validation.
J. Nucl. Med.
1998; 39(5):904-11.
43. Leahy, R. and Yan, X., Incorporation of anatomical MR data for improved
functional imaging with PET, in: Colchester, A.C.F. and Hawkes, D.J., Eds.
Information Processing in Medical Imaging
. New York: Springer-Verlag; 1991.
p. 105-120.
44. Ouyang, X., Wong, W.H., Johnson, V.E., Hu, X., and Chen, C-T., Incorporation of
correlated structural images in PET image reconstruction.
IEEE Trans. Med. Imag.
1994; MI-14(4):627-640.
45. Ardekani, B.A., Braun, M. and Hutton, B.F., Improved quantification with the
use of anatomical information in PET image reconstruction, in: Uemura, K.,
Lassen, N.A., Jones, T., and Kanno, I., Eds.
Quantification of Brain Function: Tracer
Kinetics and Image Analysis in Brain PET:
Elsevier; 1993. p. 351-362.
46.
Lange, K. and Carson, R., EM reconstruction algorithms for emission and trans-
mission tomography.
J. Comput. Assist. Tomogr.
1984; 8:306-316.
47.
Jaszczak, R.J., Chang, L.T., and Stein, N.A., Whole body single photon emission
computed tomography using large field of view scintillation cameras.
Phys. Med.
Biol.
1979; 24:1123-1143.
48.
Ardekani, B.A., Braun, M., Hutton, B.F., and Kanno, I., Minimum cross-entropy
reconstruction of PET images using prior anatomical information obtained from
MR, in: Myers, R., Cunningham, V.J., Bailey, D.L., and Jones, T., Eds.
Quantifica-
tion of Brain Function Using PET.
San Diego: Academic Press; 1996. p. 113-117.
49.
Hsu, C.H.L. and Leahy, R.M., PET Image reconstruction incorporating anatom-
ical information using segmented regression, in:
Medical Imaging 97,
SPIE; 1997;
Newport Beach CA, 1997.
50.
Ardekani, B.A., Braun, M.I.K., and Hutton, B.F., Automatic detection of intradu-
ral spaces in MR images.
J. Comput. Assist. Tomogr.
1994; 18(6):963-969.
51.
Slomka, P.J., Hurwitz, G.A., Stephenson, J., and Cradduck, T., Automated
alignment and sizing of myocardial stress and rest scans to three-dimensional
normal templates using an image registration algorithm.
J. Nucl. Med.
1995;
36(6):1115-1122.
52.
DePascquale, E.E., Nody, A.A., and DePuey, E.G., Quantitative rotational thalli-
um-201 tomography for identifying and localizing coronary artery disease.
Cir-
culation
1988; 77:316-327.
53.
Kiat, H., VanTrain, K., and Berman, D. Quantitative analysis of SPECT—Thal-
lium-201 reversibility: development and preliminary validation of an objective
method.
J. Nucl. Med.
1989; 1989:739.
54.
Gilardi, M.C., Rizzo, G., Savi, A., Landoni, C., Bettinardi, V., Rossetti, C., et al.
Correlation of SPECT and PET cardiac images by a surface matching registration
technique.
Comput. Med. Imag. Graphics
1998; 22(5):391-398.
55.
Talairach, J. and Tournoux, P.,
Co-Planar Stereotactic Atlas of the Human Brain: 3-
Dimensional Proportional System: An Approach to Cerebral Imaging
. Stuttgart: Georg
Thieme Verlag; 1988.
56.
Friston, K.J., Ashburner, J., Frith, C.D., Poline, J-B., Heather, J.D., and Frackowiak,
R.S.J., Spatial registration and normalisation of images.
Human Brain Mapping
1995;
2:165-189.