pre-intervention images of other modalities; incorporating registration algo-
rithms into the workstation controlling the interventional modality can make
this straightforward. Future developments in nonrigid registration algo-
rithms, discussed elsewhere in this topic, are likely to make these applicable
to MR-CT registration, which will open up many new applications, including
planning of surgery and radiotherapy outside the head.
References
1. G.T.Y. Chen, M. Kessler, and S. Pitluck, Structure transfer between sets of three
dimensional medical imaging data, in
Computer Graphics 1985,
pp. 171-175, Dallas:
National Computer Graphics Association, 1985.
2. T.M. Peters, J.A. Clark, A. Olivier, E.P. Marchand, G. Mawko, M. Dieumegarde,
L. Muresan, and R. Ethier, Integrated stereotaxic imaging with CT, MR imaging,
and digital subtraction angiography,
vol. 161, pp. 821-826, 1986.
3. D.N. Levin, C.A. Pelizzari, G.T.Y. Chen, C.-T. Chen, and M.D. Cooper, Retrospec-
tive geometric correlation of MR, CT, and PET images,
Radiology,
Radiology,
vol. 169,
pp. 817-823, 1988.
4. T.S. Sumanaweera, G.H. Glover, S.M. Song, J.R. Adler, and S. Napel, Quantifying
MRI geometric distortion in tissue,
vol. 31, pp. 40-47, 1994.
5. H. Chang and J.M. Fitzpatrick, A technique for accurate magnetic resonance
imaging in the presence of field inhomogeneities,
Magn. Reson. Med.,
IEEE Trans. Med. Imaging,
vol. 11, pp. 319-329, 1992.
6. L.R. Schad, R. Boesecke, W. Schlegel, G.H. Hartmann, V. Sturm, L.G. Strauss, and
W.J. Lorenz, Three dimensional image correlation of CT, MR, and PET studies
in radiotherapy treatment planning of brain tumors,
J. Comput. Assist. Tomogr.,
vol. 11, pp. 948-954, 1987.
7. J. Zhang, M.F. Levesque, C.L. Wilson, R.M. Harper, J. Engel, Jr., R. Lufkin, and
E.J. Behnke, Multi-modality imaging of brain structures for stereotactic surgery,
vol. 175, pp. 435-441, 1990.
8. D.L.G. Hill, D.J. Hawkes, J.E. Crossman, M.J. Gleeson, T.C.S. Cox, E.E.C.M.L.
Bracey, A.J. Strong, and P. Graves, Registration of MR and CT images of skull
base surgery using point-like anatomical features,
Radiology,
Br. J. Radiol.,
vol. 64, pp. 1030-
1035, 1991.
9. C.R. Maurer, Jr., J.M. Fitzpatrick, M.Y. Wang, R.L. Galloway, Jr., R.J. Maciunas,
and G.S. Allen, Registration of head volume images using implantable fiducial
markers,
IEEE Trans. Med. Imaging,
vol. 16, pp. 447-462, 1997.
10.
P.A. van den Elsen, M.A. Viergever, A.C. Van Huffelen, W. Van der Meij, and
G.H. Wieneke, Accurate matching of electromagnetic dipole data with CT and
MR images,
Brain Topogr.,
vol. 3, pp. 425-432, 1991.
11.
E.P. Sipos, S.A. Tebo, S.J. Zinreich, D.M. Long, and H. Brem,
In vivo
accuracy
testing and clinical experience with the isg viewing wand,
Neurosurgery,
vol. 39,
pp. 194-202, 1996.
12.
N.L. Dorward, O. Alberti, B. Velani, F.A. Gerritsen, W.F.J. Harkness, N.D. Kitchen,
and D.G.T. Thomas, Postimaging brain distortion: magnitude, correlates, and
impact on neuronavigation,
J. Neurosurg.,
vol. 88, pp. 656-662, 1998.
Search WWH ::