Biomedical Engineering Reference
In-Depth Information
50.
Hoffman, E.J., Phelps, M.E., Huang, S.C., Mazziotta, J., Digby, W., and Dahlbom, M.,
A new PET system for high-resolution 3-dimensional brain imaging. J. Nucl. Med .
1987; 28(4):758-759.
51.
Townsend, D.W., Wensveen, M., Byars, L.G., Geissbühler, A., Tochon-Danguy,
H.J., Christin, A., et al., A rotating PET scanner using BGO block detectors:
design, performance and applications. J. Nucl. Med . 1993; 34:1367-1376.
52.
Bailey, D.L., Young, H.E., Bloomfield, P.M., Meikle, S.R., Glass, D.E., Myers, M.J.,
et al., ECAT ART—A continuously rotating PET camera: performance charac-
teristics, comparison with a full ring system, initial clinical studies, and instal-
lation considerations in a nuclear medicine department. Eur. J. Nucl. Med . 1997;
24(1):6-15.
53.
Karp, J.S., Muehllener, G., Mankoff, D.A., Ordonez, C.E., Ollinger, J.M., Daube-
Witherspoon, M.E., et al., Continuous-slice PENN-PET: a positron tomograph
with volume imaging capability. J. Nucl. Med . 1990; 31:617-627.
54.
Townsend, D.W., Frey, P., Jeavons, A., Reich, G., Tochon-Danguy, H.J., Donath, A.,
et al., High density avalanche chamber (HIDAC) positron camera. J. Nucl. Med .
1987; 28:1554-1562.
55.
Marsden, P.K., Ott, R.J., Bateman, J.E., Cherry, S.R., Flower, M.A., and Webb, S.,
The performance of a multiwire proportional chamber positron camera for clin-
ical use. Phys. Med. Biol . 1989; 34:1043-1062.
56.
Lewellen, T.K., Miyaoka, R.S., Kaplan, M.S., Kohlmyer, S.K., Costa, W., and
Jansen, F., Preliminary investigation of coincidence imaging with a standard
dual-headed SPECT system. J. Nucl. Med . 1995; 36(5):175P (Abstract).
57.
Lang, T.F., Hasegawa, B.H., Liew, S.C., Brown, J.K., Blankespoor, S.C., and Reilly,
S.M., et al., Description of a prototype emission-transmission computed tomog-
raphy imaging system. J. Nucl. Med . 1992; 33(10):1881-1887.
58.
Kalki, K., Blankespoor, S.C., Brown, J.K., Hasegawa, B.H., Dae, M.W., Chin, M., et al.,
Myocardial perfusion imaging with a combined x-ray CT and SPECT system. J.
Nucl. Med . 1997; 38(10):1535-1540.
59.
Beyer, T., Kinahan, P.E., Townsend, D.W., and Sashin, D., The use of X-ray CT
for attenuation correction of PET data, in Trendler, R.C., Ed., IEEE Nuclear Science
Symposium and Medical Imaging Conference ; 1994; Institute of Electrical and Elec-
tronic Engineers; Norfolk, VA, 1994. 1573-1577.
60.
Shao, Y., Cherry, S.R., Farahani, K., Meadors, K., Siegel, S., and Silverman, R.W.,
et al., Simultaneous PET and MR imaging. Phys. Med. Biol . 1997; 42:1965-1970.
61.
Marsden, P.K., Shoa, Y., Cherry, S.R., Cave, A., Parkes, H.G., and Silverman, R.W.,
et al., Simultaneous acquisition of PET images and NMR spectra in a high field
magnet. J. Nucl. Med . 1997; 38(5)Supplement: 45P.
62.
Larsson, S.A., Gamma camera emission tomography. Development and proper-
ties of a multisectional emission computed tomography system. Acta Radiologica
1980; Suppl 363:30-32.
63.
Bailey, D.L., Transmission scanning in emission tomography. Eur. J. Nucl. Med .
1998; 25(7):774-787.
64.
Barry, C.D., Allott, C.P., John, N.W., Mellor, P.M., Arundel, P.A., Thomson, D.S.,
and Waterton, J.C., Three-dimensional freehand ultrasound: image reconstruc-
tion and volume analysis. Ultra. Med. Biol . 1997; 23(8):1209-24.
65.
Cosgrove, D., Meire, H., and Dewbury K., Abdominal and General Ultrasound Vol. 1.
Churchill Livingstone, Edinburgh, 1993.
66.
Prager, R.W., Rohling, R.N., Gee, A.H., and Berman, L., Rapid calibration for
3-D freehand ultrasound. Ultra. Med. Biol . 1998; 24(6):855-869.
Search WWH ::




Custom Search