Biomedical Engineering Reference
In-Depth Information
17.
Schad, L., Ehricke, H.H., Wowra, B., Layer, G., Engenhart, R., Kauczor, H.U.,
Zabel, H.J., Brix, G., and Lorenz, W.J., Correction of spatial distortion in magnetic
resonance angiography for radiosurgical treatment planning of cerebral arterio-
venous malformations. Magn. Reson. Imaging . 1992; 10:609-621.
18.
Studholme, C., Hill, D.G.H., Wong, J., Maisey, M.N., and Hawkes, D.J., Registra-
tion measures for automated 3D alignment of PET and intensity distorted MR
images. Proceedings in Image Fusion and Shape Variability , Mardia, K.V., Gill, C.A.,
and Dryden, I.L., Eds., Leeds University Press, 1996.
19.
Sumanaweera, T.S., Glover, G.H., Hemler, P.F., van den Elsen, P.A., Martin, D.,
Adler, J.R., and Napel, S., MR geometric distortion correction for improved frame-
based stereotaxic target localization accuracy. Magn. Reson. Med . 1995; 34:106-113.
20.
Mizowaki, T., Nagata, Y., Okajima, K., Murata, R., Yamamoto, M., Kokubo, M.,
Hiraoka, M., and Abe, M., Development of an MR simulator: experimental ver-
ification of geometric distortion and clinical application. Radiology . 1996; 199:
855-860.
21.
Michiels, J., Bosmans, H., Pelgrims, P., Vandermeulen, D., Gybels, J., Marchal, G.,
and Suetens, P., On the problem of geometric distortion in magnetic resonance
images for stereotactic neurosurgery. Magn. Reson. Imaging . 1994; 12(5): 749-
765.
22.
Alexander III, E., Kooy, H.M., van Herk, M., Schwartz, M., Barnes, P.D., Tarbell, N.,
Mulkern, R.V., Holupka, E.J., and Loeffler, J.S., Magnetic resonance image-directed
stereotactic neurosurgery: use of image fusion with computerized tomography
to enhance spatial accuracy. J. Neurosurg . 1995; 83:271-276.
23.
Walton, L., Hampshire, A., Forster, D.M.C., and Kemeny, A.A., Stereotactic lo-
calization with magnetic resonance imaging: a phantom study to compare the
accuracy obtained using two-dimensional and three-dimensional data acquisi-
tions. Neurosurg . 1997; 41(1):131-139.
24.
Sumanaweera, T., Adler, J.R., Napel, S., and Glover, G.H., Characterization of
spatial distortion in magnetic resonance imaging and its implications for stereo-
taxic surgery. Neurosurg . 1994; 35(4):696-704.
25.
Moerland, M.A., Beersma, R., Bhagwandien, R., Wijderman, H.K., and Bakker,
C.J.G., Analysis and correction of geometric distortions in 1.5T magnetic reso-
nance images for use in radiotherapy treatment planning. Phys. Med. Biol . 1995;
40:1651-1664.
26.
Lemieux, L., Barker, G.J., and MacManus, D.G., Important geometric distortions
in 3D gradient-echo images with rectangular field-of-view and implications for
stereotaxy, in: Proceed. Soc. Magn. Reson. 4th Scientific Meeting and Exhibition , New
York, 1996:600.
27.
Jezzard, P. and Balaban, R.S., Correction for geometric distortion in echo-planar
images from B0 field variations. Magn. Reson. Med . 1995; 34:65-73.
28.
Moseley, M.E. and Butts, K., Diffusion and Perfusion, in Stark, D.D. and Bradley,
Jr., W.G., Ed., Magnetic Resonance Imaging . C.V. Mosby; St. Louis: 1999.
29.
Chang, H. and Fitzpatrick, J.M., A technique for accurate magnetic resonance
imaging in the presence of field inhomogeneities. IEEE. Trans. Med. Imaging . 1992;
11(3):319-329.
30.
Reber, P.J., Wong, E.C., Buxton, R.B., and Frank, L.R., Correction of off-resonance-
related distortion in echo-planar imaging using EPI-based field maps. Magn.
Reson. Med . 1998; 39:328-330.
31.
Kadah, Y.M. and Hu, X., Algebraic reconstruction for magnetic resonance imag-
ing under B 0 inhomogeneity. IEEE. Trans. Med. Imag . 1998; 17(3):362-370.
Search WWH ::