Fig. 14 ( a , top ): Hydrophobicity (log D ) vs. pH curves for penciclovir and vidarabine. ( b , middle ):
Less internal standard response variation was observed while using vidarabine as the internal stan-
dard (CV = 13.02 %) but 43 % of the calibration standards (CS) and quality controls (QC) were
rejected. Extraction: MCX (mixed-mode strong cation exchange)-based solid-phase extraction.
( c , bottom ): More IS response variation was observed while using a deuterated internal standard,
penciclovir-d 4 (CV = 23.81 %) but 100 % of the CS and QC samples were accepted. Reproduced
from ref. [ 36 ] with permission from Elsevier
 