44. The following circuit is operating in the sinusoidal steady state. Find the steady-state
expression for
v c
if
v s ¼
10 sin 1000
t
V.
i L
5 Ω
+
v C
+
v s
3 H
6 F
20 Ω
45. The following circuit is operating in the sinusoidal steady state. Find the steady-state
expression for
i L if
i s ¼
5 cos 500
t
A.
i L
+
v C
i s
10 Ω
2 H
15 F
46. The following circuit is operating in the sinusoidal steady state. Find the steady-state
expression for
v c
if
i s ¼
25 cos 4000
t
V.
i L
4
Ω
+
v C
v s
4
16 H
1 F
Ω
47. Design a low-pass filter with a magnitude of 10 and a cutoff frequency of 250 rad
s .
48. Design a high-pass filter with a magnitude of 20 and a cutoff frequency of 300 rad
s .
49. Design a band-pass filter with a gain of 15 and passthrough frequencies from 50 to 200 rad
s
.
50. Design a low-pass filter with a magnitude of 5 and a cutoff frequency of 200 rad
s .
51. Design a high-pass filter with a magnitude of 10 and a cutoff frequency of 500 rad
s .
52. Design a band-pass filter with a gain of 10 and passthrough frequencies from 20 to 100 rad
s
.