Biomedical Engineering Reference
In-Depth Information
8. J. Frew and H.A. Hill, Electrochemical biosensors. Anal. Chem. 59 , 933A-939A (1987).
9. P. Hilditch and M. Green, Disposable electrochemical biosensors. Analyst 116 , 1217-1220 (1991).
10. D. Matthews, R. Holman, E. Brown, J. Streemson, A. Watson, and S. Hughes, Pen-sized digital 30-second
blood glucose meter. Lancet 2 , 778-779 (1987).
11. R.W. Murray, A. Ewing, and R. Durst, Chemically modifi ed electrodes - molecular design for Electroanalysis.
Anal. Chem. 59 , 379A-384A (1987).
12. Y. Degani and A. Heller, Direct electrical communication between chemically modifi ed enzymes and
metal electrodes. I. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound
covalently to the enzyme. J. Phys. Chem. 91 , 1285-1289 (1987).
13. I. Willner, V. Heleg-Shabtai, R. Blonder, E. Katz, and G. Tao, Electrical wiring of glucose oxidase by
reconstitution of FAD-modifi ed monolayers assembled onto Au-electrodes. J. Am. Chem. Soc. 118 ,
10 321-10 322 (1996).
14. D. Bindra, Y. Zhang, G. Wilson, R. Sternberg, D.Trevenot, G. Reach, and D. Moatti, Design and in
vitro studies of a needle-type glucose sensor for subcutaneous monitoring. Anal. Chem. 63 , 1692-1696
(1991).
15. E. Csoregi, D.W. Schmidtke, and A. Heller, Design and optimzation of a selective subcutaneously
implantable gluocse electrode based on wired glucose oxidase. Anal. Chem . 67 , 1240-1244 (1995).
16. S. Emr and A. Yacynych, Use of polymer fi lms in amperometric biosensors. Electroanalysis 7 , 913-923
(1995).
17. C. Malitesta, F. Palmisano, L. Torsi, and P. Zambonin, Glucose fast-response amperometric sensor based
on glucose oxidase immobilized in an electropolymerized poly(o-phenylenediamine) fi lm. Anal. Chem.
62 , 2735-2740 (1990).
18. S. Sasso, R. Pierce, R. Walla, and A. Yacynych, Electropolymerized 1,2-diaminobenzene as a means to
prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors.
Anal. Chem. 62 , 1111-1117 (1990).
19. Y. Zhang, Y. Hu, G.S. Wilson, D. Moatti-Sirat, V. Poitout, and G. Reach, Elimination of the acetami-
nophen interference in an implantable glucose sensor. Anal. Chem. 66 , 1183 (1994).
20. J. Wang, J. Liu, L. Chen, and F. Lu, Highly selective membrane-free, mediator-free glucose biosensor.
Anal. Chem. 66 , 3600-3603 (1994).
21. J. Newman, S. White, I. Tothill, and A.P. Turner, Catalytic materials, membranes, and fabrication tech-
nologies suitable for the construction of amperometric biosensors. Anal. Chem . 67 , 4594-4599 (1995).
22. A. Karaykin, O. Gitelmacher, and E. Karaykina, Prussian blue-based fi rst-generation biosensor. A sensi-
tive amperometric electrode for glucose. Anal. Chem. 67 , 2419-2423 (1995).
23. Q. Chi and S. Dong, Amperometric biosensors based on the immobilization of oxidases in a Prussian
blue fi lm by electrochemical codeposition. Anal. Chim. Acta 310 , 429-436 (1995).
24. J. Wang and H. Wu, Highly selective biosensing of glucose utilizing a glucose oxidase
rhodium
Nafi onĀ® biocatalytic-electrocatalytic-permselective surface microstructure. J. Electroanal. Chem. 395 ,
287-291 (1995).
25. D. Gough, J. Lucisano, and P. Tse, Two-dimensional enzyme electrode sensor for glucose. Anal. Chem.
57 , 2351-2357 (1985).
26. J. Armour, J. Lucisano, and D. Gough, Application of chronic intravascular blood glucose sensor in
dogs. Diabetes 39 , 1519-1526 (1990).
27. J. Wang and F. Lu, Oxygen-rich oxidase enzyme electrodes for operation in oxygen-free solutions. J.
Am. Chem. Soc. 120 , 1048-1050 (1998).
28. E. D'Costa, J. Higgins, and A.P. Turner, Quinoprotein glucose dehydrogenase and its application in an
amperometric glucose sensor. Biosensors 2 , 71-87 (1986).
29. R.A. Marcus and N. Sutin, Electron transfers in chemistry and biology. Biochim. Biophys. Acta 811 ,
265-322 (1985).
30. I. Willner and E. Katz, Integration of layered redox proteins and conductive supports for bioelectronic
applications. Angew Chem. Int. Ed. 39 , 1180-1218 (2000).
31. A.P.F. Turner, B. Chen, and S.A. Piletsky, In vitro diagnostics in diabetes: meeting the challenge.
Clinical Chemistry 45 , 1596-1601 (1999).
Search WWH ::