Biomedical Engineering Reference
In-Depth Information
57. X.C. He and J.Y. Mo, Electrocatalytic oxidation of NO at electrode modifi ed with Nafi on-Co-II-1,
10-phenanthroline fi lm and its application to NO detection. Analyst 125 , 793-795 (2000).
58. S.R. Smith and H.H. Thorp, Application of the electrocatalytic reduction of nitric oxide mediated by
ferrioxamine B to the determination of nitric oxide concentrations in solution. Inorg. Chim. Acta 273 ,
316-319 (1998).
59. Y. Kitamura, T. Uzawa, K. Oka, Y. Komai., H. Ogawa, N. Takizawa, H. Kobayashi, and K. Tanishita,
Microcoaxial electrode for in vivo nitric oxide measurement. Anal. Chem. 72 , 2957-2962 (2000).
60. F. Mizutani, S. Yabuki, T. Sawaguchi, Y. Hirata,Y. Sato, and S. Iijima, Use of a siloxane polymer for the
preparation of amperometric sensors: O-2 and NO sensors and enzyme sensors. Sens. Actuator B-Chem.
76 , 489-493 (2001).
61. J. Katrlik and P. Zalesakova, Nitric oxide determination by amperometric carbon fi ber microelectrode.
Bioelectrochemistry 56 , 73-76 (2002).
62. C.H. Fan, J.T. Pang, P.P. Shen, G.X. Li, and D.X. Zhu, Nitric oxide biosensors based on Hb/phosphati-
dylcholine fi lms. Anal. Sci. 18 , 129-132 (2002).
63. C.H. Fan, G.X. Li, J.Q. Zhu, and D.X. Zhu, A reagentless nitric oxide biosensor based on hemoglobin-
DNA fi lms. Anal. Chim. Acta 423 , 95-100 (2000).
64. A. Kitajima, T. Teranishi, and M. Miyake, Detection of nitric oxide on carbon electrode modifi ed with
ionic polymers and alpha-cyclodextrin. Electrochemistry 69 , 16-20 (2001).
65. J.H. Shin, S.W. Weinman, and M.H. Schoenfi sch, Sol-gel derived amperometric nitric oxide microsen-
sor. Anal. Chem. 77 , 3494-3501 (2005).
66. Y. Lee, B.K. Oh, and M.E. Meyerhoff, Improved planar amperometric nitric oxide sensor based on plati-
nized platinum anode. 1. Experimental results and theory when applied for monitoring NO release from
diazeniumdiolate-doped polymeric fi lms. Anal. Chem. 76 , 536-544 (2004).
67. Y. Lee, J. Yang, S.M. Rudich, R.J. Schreiner, and M.E. Meyerhoff, Improved planar amperometric nitric
oxide sensor based on platinized platinum anode. 2. Direct real-time measurement of NO generated
from porcine kidney slices in the presence of L-arginine, L-arginine polymers, and protamine. Anal.
Chem. 76 , 545-551 (2004).
68. S. Kroning, F.W. Scheller, U. Wollenberger, and F. Lisdat, Myoglobin-clay electrode for nitric oxide
(NO) detection in solution. Electroanalysis 16 , 253-259 (2004).
69. K. Kamei, T. Haruyama, M. Mie, Y. Yanagida, M. Aizawa, and E. Kobatake, The construction of
endothelial cellular biosensing system for the control of blood pressure drugs. Biosens. Bioelectron. 19 ,
1121-1124 (2004).
70. E. Casero, F. Pariente, and E. Lorenzo, Electrocatalytic oxidation of nitric oxide at indium hexacyanof-
errate fi lm-modifi ed electrodes. Anal. Bioanal. Chem. 375 , 294-299 (2003).
71. A. Pailleret, J. Oni, S. Reiter, S. Isik, M. Etienne, F. Bedioui, and W. Schuhmann, In situ formation and
scanning electrochemical microscopy assisted positioning of NO-sensors above human umbilical vein
endothelial cells for the detection of nitric oxide release. Electrochem. Commun. 5 , 847-852 (2003).
72. H.I. Magazine, Detection of endothelial cell-derived nitric oxide: current trends and future directions.
Adv. Neuroimmunol. 5 , 479-490 (1995).
73. F.L. Kiechle and T. Malinski, Nitric-oxide - biochemistry, pathophysiology, and detection. Am. J. Clin.
Pathol. 100 , 567-575 (1993).
74. S. Archer, Measurement of nitric-oxide in biological models. Faseb J. 7 , 349-360 (1993).
75. Handbook of Chemistry and Physics ; 76th ed.; CRC Press: Boca Raton, FL, 1995.
76. M. Kelm and J. Schrader, Control of coronary vascular tone by nitric-oxide. Circ. Res. 66 , 1561-1575
(1990).
77. X.J. Zhang, L. Cardosa, M. Broderick, H. Fein, and I.R. Davies, Novel calibration method for nitric
oxide microsensors by stoichiometrical generation of nitric oxide from SNAP. Electroanalysis 12 , 425-428
(2000).
78. M. Tristani-Firouzi, E.G. DeMaster, B.J. Quast, D.P. Nelson, and S.L. Archer, Utility of a nitric oxide
electrode for monitoring the administration of nitric oxide in biologic systems. J. Lab. Clin. Med. 131 ,
281-285 (1998).
79. J.C. Millar, Real-time direct measurement of nitric oxide in bovine perfused eye trabecular meshwork
using a Clark-type electrode. J. Ocular Pharmacol. Ther. 19 , 299-313 (2003).
Search WWH ::




Custom Search