Biomedical Engineering Reference
In-Depth Information
114. J. Gabel, W. Vonau, P. Shuk, and U. Guth, New reference electrodes based on tungsten-substituted
molybdenum bronzes.
Solid State Ionics
169
, 75-80 (2004).
115. G. Valdes-Ramirez, G.A. Alvarez-Romero, C.A. Galan-Vidal, P.R. Hernandez-Rodrguez, and
M.T. Ramrez-Silva, Composites: a novel alternative to construct solid state Ag/AgCl reference elec-
trodes.
Sens. Actuators
B.
110
, 264-270 (2005).
116. S. Martin, J. Ha, J. Kim, T. Strong, G. Cha, and R. Brown, ISE arrays with improved dynamic
response and lifetime, in
Tech. Digest of the Solid-State Sensor, Actuator, and Microsystems Workshop
,
pp. 396-399. Hilton Head, SC (2004).
117. H. Kaden, H. Jahn, and M. Berthold, Study of the glass/polypyrrole interface in an all-solid-state pH
sensor.
Solid State Ionics
169
, 129-133 (2004).
118. M. Trojanowicz, Application of conducting polymers in chemical analysis.
Microchim. Acta
143
,
75-91 (2003).
119. J.E. Zachara, R. Toczylowska, R. Pokrop, M. Zagorska, A. Dybko, and W. Wroblewski, Miniaturised
all-solid-state potentiometric ion sensors based on PVC-membranes containing conducting polymers.
Sens. Actuators B.
101
, 207-212 (2004).
120. L. He and C.S. Toh, Recent advances in analytical chemistry - a material approach.
Anal. Chim. Acta
556
, 1-15 (2006).
121. A.J. Tudos, G.A.J. Besselink, and R.B.M. Schasfoort, Trends in miniaturized total analysis systems for
point-of-care testing in clinical chemistry.
Lab on a Chip
1
, 83-95 (2001).
122. I. Moser, G. Jobst, and G.A. Urban, Biosensor array for simultaneous measurement of glucose, lactate,
glutamate, and glutamine.
Biosens. Bioelectron.
17
, 297-302 (2002).
123. D. Diamond, Overview, in
Principles of Chemical and Biological Sensors Chemical Analysis: A Series
of Monographs on Analytical Chemistry and Its Applications
(D. Diamond, ed.), pp. 1-18. John Wiley &
Sons, Inc., New York (1998).
124. D. Zhou and R. Greenberg, Microsensors and microbiosensors for retinal implants.
Frontiers in Biosci
.
10
, 166-179 (2005).
125. D. Bingham, J. Kendall, and M. Clancy, The portable laboratory: an evaluation of the accuracy and
reproducibility of i-STAT.
Ann. Clin. Biochem.
36
, 66-71 (1999).
126. M. Ganter and A. Zollinger, Continuous intravascular blood gas monitoring: development, current
techniques, and clinical use of a commercial device.
Bri. J. Anaesthesia
91
, 397-407 (2003).
127. K.R. Khabbaz, F. Zankoul, and K.G. Warner, Intraoperative metabolic monitoring of the heart:
II. Online measurement of myocardial tissue pH.
Ann. Thorac. Surg.
72
, S2227-S2234 (2001).
128. C.C. Liu, B.K. Ahn, E.G. Brown, and M.R. Neuman, Engineering development & evaluation of
implantable pO
2
, pH and pCO
2
sensors, in
Proceedings of the First Pacifi c Chemical Eng. Conference
,
p. 144. Kyoto, Japan (1972).
129. M.A. Afromowitz and S.S. Yee, Fabrication of pH-sensitive implantable electrode by thick-fi lm hybrid
technology.
J. Bioeng.
1
, 55-60 (1977).
130. M. Telting-Diaz, M.E. Collison, and M.E. Meyerhoff, Simplifi ed dual lumen catheter design for simul-
taneous potentiometric monitoring of carbon dioxide and pH.
Anal. Chem.
66
, 576-583 (1994).
131. J.F. Martinez-Tica, R. Berbarie, P. Davenport, and M.H. Zornow, Monitoring brain pO
2
, pCO
2
, and pH
during graded levels of hypoxemia in rabbits.
J. Neurosurg. Anesthesiol
.
11
, 260-263 (1999).
132. A. Jabre, Y. Bao, and E.L. Spatz, Brain pH monitoring during ischemia.
Surg. Neurol.
54
, 55-58
(2000).
133. M.C. Frost and M.E. Meyerhoff, Implantable chemical sensors for real-time clinical monitoring:
progress and challenges.
Curr. Opin. Chem. Biol.
6
, 633-641 (2002).
134. M.C. Frost, M.M. Reynolds, and M.E. Meyerhoff, Polymers incorporating nitric oxide releasing/gener-
ating substances for improved biocompatibility of blood-contacting medical devices.
Biomaterials
26
,
1685-1693 (2005).
135. D.A. Gough and J.C. Armour, Development of the implantable glucose sensor. What are the prospects
and why is it taking so long?
Diabetes
44
, 1005-1009 (1995).
136. A. Heller, Implanted electrochemical glucose sensors for the management of diabetes.
Annu. Rev.
Biomed. Eng.
1
, 153-175 (1999).
Search WWH ::
Custom Search