Biomedical Engineering Reference
In-Depth Information
19. D. Zhou, A. Chu, A. Agazaryan, A. Istomin, and R. Greenberg, Towards an implantable micro pH
electrode array for visual prostheses, in Nanoscale Devices, Materials, and Biological Systems:
Fundamentals and Applications (M. Cahay, ed.), pp. 563-576. Electrochemical Society (2004).
20. A. Chvatal, P. Jendelova, N. Krizi, and E. Sykova, Stimulation-evoked changes in extracellular pH,
calcium and potassium activity in the frog spinal cord. Physiologia Bohemoslovaca. 37 , 203-212
(1988).
21. B.J. Venton, D.J. Michael, and R.M. Wightman, Correlation of local changes in extracellular oxygen
and pH that accompany dopaminergic terminal activity in the rat caudate-putamen. J. Neurochem . 84 ,
373-381 (2003).
22. Y. Miao, J. Chen, and K. Fang, New technology for the detection of pH. J. Biochem. Biophys. Methods
63 , 1-9 (2005).
23. K.J. Albert, C.L. Schauer, and D.R. Walt, Optical sensor arrays for medical diagnostics, in Biomedical
Diagnostic Science and Technology (W. Law, N. Akmal, and A Usmani, eds), pp. 121-138. Marcel
Dekker, NY (2002).
24. T.M. Butler, B. MacCraith, and C. McDonagh, Leaching in sol-gel derived silica fi lms for optical sens-
ing. J. Non-Cryst. Solids 224 , 249-258 (1998).
25. A. Lobnik, I. Oehme, I. Murkovic, and O. Wolfbeis, pH optical sensors based on sol-gels: chemical dop-
ing versus covalent immobilization. Anal. Chim. Acta 367 , 159-165 (1998).
26. L.S. Wong, W.S. Brocklesby, and M. Bradleya, Fibre optic pH sensors employing tethered non-fl uorescent
indicators on macroporous glass. Sens. Actuators B . 107 , 957-962 (2005).
27. C. Bock, F.J. Sartoris, R.M. Wittig, and H.O. Portner, Temperature-dependent pH regulation in steno-
thermal antarctic and eurythermal temperate eelpout (Zoarcidae): an in-vivo NMR study. Polar Biol . 24 ,
869-874 (2001).
28. M. Foster, I. Grigorev, D. Lurie, V. Khramtsov, S. McCallum, I. Panagiotelis, J. Hutchison, A. Koptioug,
and I. Nicholson, In vivo detection of a pH-sensitive nitroxide in the rat stomach by low-fi eld ESR-
based techniques. Magn. Reson. Med . 49 , 558-567 (2003).
29. S. Zhang, B. Soller, and R. Micheels, Partial leastsquares modeling of near infrared refl ectance data for
noninvasive in-vivo determination of deep tissue pH. Appl. Spectroscopy 52 , 400-406 (1998).
30. T. Khan, B. Soller, M. Naghavi, and W. Casscells, Tissue pH determination for the detection of metabol-
ically active, infl amed vulnerable plaques using near-infrared spectroscopy: an in-vitro feasibility study.
Cardiol. 103 , 10-16 (2005).
31. J. Puyana, B. Soller, S. Zhang, and S. Heard, Continuous measurement of gut pH with near infrared
spectroscopy during hemorrhagic shock. J. Trauma 46 , 9-15 (1999).
32. G. Horvai and E. Pungor, Amperometric determination of hydrogen and hydroxyl ion concentrations in
unbuffered solutions in the pH range 5-9. Anal. Chim. Acta 243 , 55-59 (1991).
33. J.E. Pandolfi no, S. Ghosh, Q. Zhang, M. Heath, T. Bombeck, and P.J. Kahrilas, Slimline vs. glass pH elec-
trodes: what degree of accuracy should we expect? Alimentary Pharmacol. & Therapeutics 23 , 331-340
(2006).
34. G.T. Hanson, T.B. McAnaney, E.S. Park, M.E. Rendell, D.K. Yarbrough, S. Chu, L. Xi, S. Boxer,
M. Montrose, and S. Remington, Green fl uorescent protein variants as ratiometric dual emission pH sen-
sors. 1. Structural characterization and preliminary application. Biochem . 41 , 15 477-15 488 (2002).
35. X.J. Zhang, B. Ogorevc, and J. Wang, Solid-state pH nanoelectrode based on polyaniline thin fi lm elec-
trodeposited onto ion-beam etched carbon fi ber. Anal. Chim. Acta 452 , 1-10 (2002).
36. M.S. Frant, History of the early commercialization of ion-selective electrodes. Analyst 199 , 2293-2301
(1994).
37. R.W. Burnett, A.K. Covington, N.F. Andersen, W.R. Kulpmann, A. Lewenstam, A.H.J. Maas,
O. Muller-Plathe, A.L.VanKessel, and W.G. Zijlstra, Use of ion-selective electrodes for blood-electrolyte
analysis. Recommendations for nomenclature, defi nitions and conventions. Clin. Chem. Lab. Med. 38 ,
363-370 (2000).
38. R.P. Buck, S. Rondinini, A.K. Covington, F.G. Baucke, C.M. Brett, M.F. Camoes, M.J. Milton,
T. Mussini, R. Naumann, K.W. Pratt, P. Spitzer, and G.S. Wilson, The measurement of pH - defi nition,
standards and procedures (IUPAC Recommendations 2002). Pure Appl. Chem . 74 , 2169-2200 (2002).
Search WWH ::




Custom Search