Biomedical Engineering Reference
In-Depth Information
85. A. Malon, A. Radu, W. Qin, Y. Qin, A. Ceresa, M. Maj-Zurawska, E. Bakker, and E. Pretsch,
Improving the detection limit of anion-selective electrodes: an iodide-selective membrane with a
nanomolar detection limit. Anal. Chem. 75 , 3865-3871 (2003).
86. S. Makarychev-Mikhailov, A. Legin, J. Mortensen, S. Levitchev, and Y. VLASOV, Potentiometric and
theoretical studies of the carbonate sensors based on 3-bromo-4-hexyl-5-nitrotrifl uoroacetophenone.
Analyst 129 , 213-218 (2004).
87. E. Bakker and E. Pretsch, Lipophilicity of tetraphenylborate derivatives as anionic sites in neutral car-
rier-based solvent polymeric membranes and lifetime of corresponding ion-selective electrochemical
and optical sensors. Anal. Chim. Acta 309 , 7-17 (1995).
88. Y. Qin and E. Bakker, A copolymerized dodecacarborane anion as covalently attached cation exchanger
in ion-selective sensors. Anal. Chem. 75 , 6002-6010 (2003).
89. V.V. Egorov, E.M. Rakhman'ko, E.B. Okaev, E.V. Pomelenok, and V.A. Nazarov, Effects of ion associ-
ation of lipophilic quaternary ammonium salts in ion-exchange and potentiometric selectivity. Talanta
63 , 119-130 (2004).
90. R. Eugster, T. Rosatzin, B. Rusterholz, B. Aebersold, U. Pedrazza, D. Ruegg, A. Schmid, U.E.
Spichiger, and W. Simon, Plasticizers for liquid polymeric membranes of ion-selective chemical sen-
sors. Anal. Chim. Acta 289 , 1-13 (1994).
91. Y. Qin, S. Peper, A. Radu, A. Ceresa, and E. Bakker, Plasticizer-free polymer containing a covalently
immobilized Ca2 + -selective ionophore for potentiometric and optical sensors. Anal. Chem. 75 , 3038-
3045 (2003).
92. P. Anker, E. Wieland, D. Ammann, R.E. Dohner, R. Asper, and W. Simon, Neutral carrier based ion-
selective electrode for the determination of total calcium in blood-serum. Anal. Chem. 53 , 1970-1974
(1981).
93. P.G. Boswell and P. Buhlmann, Fluorous bulk membranes for potentiometric sensors with wide selectivity
ranges: observation of exceptionally strong ion pair formation. J. Am. Chem. Soc. 127 , 8958-8959 (2005).
94. R.W. Cattrall and H. Freiser, Coated wire ion selective electrodes. Anal. Chem. 43 , 1905-1906 (1971).
95. M. Fibbioli, W.E. Morf, M. Badertscher, N.F. de Rooij, and E. Pretsch, Potential drifts of solid-contacted
ion-selective electrodes due to zero-current ion fl uxes through the sensor membrane. Electroanalysis 12 ,
1286-1292 (2000).
96. K.Y. Chumbimuni-Torres, N. Rubinova, A. Radu, L.T. Kubota, and E. Bakker, A universal recipe for
solid contact potentiometric sensors for trace level measurements. (Submitted 2005)
97. M. Vazquez, J. Bobacka, M. Luostarinen, K. Rissanen, A. Lewenstam, and A. Ivaska, Potentiometric
sensors based on poly(3,4-ethylenedioxythiophene) (PEDOT) doped with sulfonated calix[4]arene and
calix[4]resorcarenes. J. Solid State Electrochem. 9 , 312-319 (2005).
98. A. Lewenstam, J. Bobacka, and A. Ivaska, Mechanism of ionic and redox sensitivity of p-type conduct-
ing polymers. 1. Theory. J. Electroanal. Chem. 368 , 23-31 (1994).
99. M.H. Schoenfi sch, K.A. Mowery, M.V. Rader, N. Baliga, J.A. Wahr, and M.E. Meyerhoff, Improving
the thromboresistivity of chemical sensors via nitric oxide release: fabrication and in vivo evaluation of
NO-releasing oxygen-sensing catheters. Anal. Chem. 72 , 1119-1126 (2000).
100. M.J. Berrocal, R.D. Johnson, I.H.A. Badr, M. Liu, D. Gao, and L.G. Bachas, Improving the blood
compatibility of ion-selective electrodes by employing poly(MPC-co-BMA), a copolymer containing
phosphorylcholine, as a membrane coating. Anal. Chem. 74 , 3644-3648 (2002).
101. M.J. Berrocal, I.H.A. Badr, D. Gao, and L.G. Bachas, Reducing the thrombogenicity of ion-selective
electrode membranes through the use of a silicone-modifi ed segmented polyurethane. Anal. Chem. 73 ,
5328-5333 (2001).
102. O.T. Guenat, J.F. Dufour, P.D. van der Wal, W.E. Morf, N.F. de Rooij, and M. Koudelka-Hep,
Microfabrication and characterization of an ion-selective microelectrode array platform. Sens.
Actuators, B 105 , 65-73 (2005).
103. W. Wroblewski, A. Dybko, E. Malinowska, and Z. Brzozka, Towards advanced chemical microsensors -
an overview. Talanta 63 , 33-39 (2004).
104. B.D. Pendley, R.E. Gyurcsanyi, R.P. Buck, and E. Lindner, A chronoamperometric method to esti-
mate changes in the membrane composition of ion-selective membranes. Anal. Chem. 73 , 4599-4606
(2001).
Search WWH ::