Figure 8. A. Fabricated (100 nm) 2 gold nanoelectrode; B. Cartoon of hydrogenase immobilized on the nanoelectrode; C. Background-subtracted
voltammogram, revealing the proton-reduction current generated by ~20 hydrogenase molecules (scan rate 1.5 mV/s, pH 5.7; 1 fA = 6250 elec-
trons/s). Adapted with permission from Ref. 169, Copyright (2008) American Chemical Society.
 