Biomedical Engineering Reference
In-Depth Information
3. Anderson JM (2001) Biological responses to materials. Annu Rev Mater Res 31:81-110
4. Arima Y, Iwata H (2007) Effect of wettability and surface functional groups on protein
adsorption
and
cell
adhesion
using
well-defined
mixed
self-assembled
monolayers.
Biomaterials 28:3074-3082
5. ASTM F720 (1981) Standard Practice for Testing Guinea Pigs for Contact Allergens:
Guinea
Pig
Maximization
Test.
West
Conshohocken,
PA
19428-2959,
USA,
ASTM
international
6. ASTM F895 (1984) Standard Test Method for Agar Diffusion Cell Culture Screening for
Cytotoxicity. West Conshohocken, PA 19428-2959, USA, ASTM international
7. ASTM F748 (2006) Standard Practice for Selecting Generic Biological Test Methods for
Materials and Devices. West Conshohocken, PA 19428-2959, USA, ASTM international
8. ASTM (2011) ''F04 on medical and surgical materials and devices.'' Retrieved 28.6.2011,
9. ASTM F719 (1981) Standard Practice for Testing Biomaterials in Rabbits for Primary Skin
Irritation ASTM international West Conshohocken, PA 19428-2959 USA
10. Babich H, Borenfreund E (1987) Structure-activity relationship (SAR) model established in
vitro with the neutral red cytotoxicity assay. Toxicol In Vitro 1:3-9
11. Bakand S, Winder C, Khalil C et al (2006) A novel in vitro exposure technique for toxicity
testing of selected volatile organic compounds. J Environ Monit 8:100-105
12. Baron MJ, Tsai C-J, Donahue SW (2010) Mechanical stimulation mediates gene expression
in MC3T3 osteoblastic cells differently in 2D and 3D environments. J Biomech Eng
132:e041005
13. Bass DA, Parce JW, Dechatelet LR et al (1983) Flow cytometric studies of oxidative
product formation by neutrophils: a graded response to membrane stimulation. J Immunol
130:1910-1917
14. bcc-Research (Market-Forecasting). (2011). Healthcare. The Market for Minimally Invasive
Medical Devices.
Report Code: HLC051E Published: March 2009
Retrieved 28.6.2011, 2011.
15. Bellows CG, Heersche JNM, Aubin JE (1999) Aluminum accelerates osteoblastic
differentiation but is cytotoxic in long-term rat calvaria cell cultures. Calcif Tissue Int 65:59-65
16. Belyanskaya L, Manser P, Spohn P et al (2007) The reliability and limits of the MTT
reduction assay for carbon nanotubes-cell interaction. Carbon 45(13):2643-2648
17. Benigni R, Bossa C, Guilliani A et al (2010) Exploring in vitro/in vivo correlation: Lessons
learned from analyzing phase I results of the US EPA's ToxCast project. J Environ Sci
Health C 28:272-286
18. Bernas T, Dobrucki J (2002) Mitochondrial and nonmitochondrial reduction of MTT:
interaction
of
MTT
with
TMRE,
JC-1,
and
NAO
mitochondrial
fluorescent
probes.
Cytometry 47:236-242
19. Berridge MV, Herst PM, Tan AS (2005) Tetrazolium dyes as tools in cell biology: new
insights into their cellular reduction. Biotechnol Annu Rev 11:127-152
20. Bhatia SK, Yetter AB (2008) Correlation of visual in vitro cytotoxicity ratings of
biomaterials with quantitative in vitro cell viability measurements. Cell Biol Toxicol
24:315-319
21. Bigerelle M, Giljean S, Anselme K (2011) Existence of a typical threshold in the response of
human mesenchymal stem cells to a peak and valley topography. Acta Biomater (in press)
22. Bonini MG, Rota C, Tomasi A et al (2006) The oxidation of 2
0
,7
0
-dichlorofluorescin to
reactive oxygen species: a self-fulfilling prophesy? Free Radic Biol Med 40:968-975
23. Born
A-K,
Rottmar
M,
Lischer
S
et
al
(2009)
Correlating
cell
architecture
with
osteogenesis: first steps towards live single cell monitoring. Eur Cell Mater 18:49-62
24. Brama M, Rhodes N, Hunt J et al (2007) Effect of titanium carbide coating on the
osseointegration response in vitro and in vivo. Biomaterials 28:595-608
25. Brodbeck WG, Colton E, Anderson JM (2003) Effects of adsorbed heat labile serum
proteins
and
fibrinogen
on
adhesion
and
apoptosis
of
monocytes/macrophages
on
biomaterials. J Mater Sci Mater Med 14:671-675
Search WWH ::
Custom Search