Biomedical Engineering Reference
In-Depth Information
Inverse analysis of the aspiration measurements enabled defining a representative
liver model including Glisson's capsule and parenchyma. The results of this work
can also be used as a relevant benchmark for simulation of the mechanical behavior
of human liver.
The cases in which aspiration data can provide diagnostic information were iden-
tified. The aspiration technique was shown to yield to a sensitivity similar to the one
of (un-blinded) digital palpation by an experienced surgeon.
As a note, by now the aspiration technique has been further developed for ap-
plication during laparoscopy. Technical details for this novel setup and first results
from corresponding in vivo measurements are found in Hollenstein et al. ( 2011 ).
Acknowledgements We thank Dr. S. Breitenstein, University Hospital Zurich, for performing
the intraoperative measurements with the aspiration device. This work was partly supported by the
CO-ME/NCCR research network of the Swiss National Science Foundation.
References
Bauer M, Mazza E, Jabareen M, Sultan L, Bajka M, Lang U, Zimmermann R, Holzapfel GA (2009)
Assessment of the in vivo biomechanical properties of the human uterine cervix in pregnancy
using the aspiration test: a feasibility study. Eur J Obstet Gynecol Reprod Biol 144:S77-S81
Brown JD, Rosen J, Kim YS, Chang L, Sinananand M, Hannaford B (2003) In-vivo and in-situ
compressive properties of porcine abdominal soft tissues. In: Westwood JD, Hoffman HM, Mo-
gel GT, Phillips R, Robb RA, Stredney D (eds) Medicine meets virtual reality 11. Studies in
health technology and informatics, vol 94. IOS Press, Amsterdam, pp 26-32
Bürzle W, Haller C, Ehrbar M, Mazza E (2012) Experimental investigations of fetal membrane
mechanics. In: Holzapfel GA (ed) CD-ROM proceedings of the European solid mechanics con-
ference 2012, Graz, Austria
Carter FJ, Frank TG, Davies PJ, McLean D, Cuschieri A (2001) Measurement and modelling of
the compliance of human and porcine organs. Med Image Anal 5:231-236
Chui C, Kobayashi E, Chen X, Hisada T, Sakuma I (2007) Transversely isotropic properties of
porcine liver tissue: experiments and constitutive modelling. Med Biol Eng Comput 45:99-106
Egger J (2008) An inflation device for testing human fetal membranes. Master's Thesis, ETH,
Zurich
Gao Z, Lister K, Desai JP (2010) Constitutive modeling of liver tissue: experiment and theory. Ann
Biomed Eng 38:505-516
Hollenstein M (2011) PhD Thesis, No. 19587, ETH, Zurich
Hollenstein M, Jabareen M, Breitenstein S, Riener M-O, Clavien P-A, Bajka M, Mazza E (2009)
Intraoperative mechanical characterization of human liver. Proc Appl Math Mech 9:83-86
Hollenstein M, Bugnard G, Joos R, Kropf S, Villiger P, Mazza E (2011) Towards laparoscopic
tissue aspiration. Med Image Anal (submitted)
Huwart L, Peeters F, Sinkus R, Annet L, Salameh N, ter Beek LC, Horsmans Y, Van Beers BE
(2006) Liver fibrosis: non-invasive assessment with MR elastography. NMR Biomed 19:173-
179
Kerdok A, Ottensmeyer M, Howe R (2006) Effects of perfusion on the viscoelastic characteristics
of liver. J Biomech 39:2221-2231
Mazza E, Nava A, Hahnloser D, Jochum W, Bajka M (2007) The mechanical response of human
liver and its relation to histology: an in vivo study. Med Image Anal 11:663-672
Mazza E, Grau P, Hollenstein M, Bajka M (2008) Constitutive modeling of human liver based on
in vivo measurements. Med Image Comput Comput Assist Interv 11:726-733
Search WWH ::




Custom Search