300mm
PBS
λ /2
balanced
detector
Figure 5.11 Schematic view of Bob's setup, using an electro-optical modulator to
change between S 2 and S 3 measurement.
focusing lens (see Figure 5.12). It transmits 52% of the incoming light and
reflects 48%. The reflected light is retarded with a quarter-wave plate, to mea-
sure its S 3 parameter on a second detector, similar to the one described above.
The remaining light is detected by the initial detector to give a measurement
of the S 2 parameter. Both detectors can be read out simultaneously. Figure 5.10
shows the combination of both setups that was used in the experiment as a
reciever setup enabling us to make different performance tests.
300mm
PBS
BS
λ /4a
balanced
detector
λ /2
PBS
balanced
detector
Figure 5.12 Schematic view of Bob's setup, using two detection setups to measure
simultaneously S 2 and S 3 with a loss of 50%. If the quarter-wave plate is removed, S 2
can be measured on both halves of the original beams.