Summary
Bioceramic coating by PVD and CVD on metallic biomaterials has been discussed, focus-
ing on improving the bone compatibility of metallic biomaterials. Finally, the relationship
between process parameters and phase, structure, and properties of coatings prepared
by RF magnetron sputtering and thermal and laser CVD, which have been the main pro-
cesses discussed in this chapter, are shown in Table 7.5. The vapor deposition can be prom-
ising processes for preparation of bioceramic coatings because it can provide well-defined
coatings by adjusting many process parameters.
Research and development of bioceramic coatings for applications to hard tissue replace-
ments will continue. Bioceramic coating by vapor deposition is a promising surface modi-
fication method accommodating mechanical, chemical, and biomedical properties.
References
1. Brånemark, P.-I., Hansson, B.O., and Adell, R., et al. 1977. Osseointegrated implants in the treat-
ment of the edentulous jaw, experience from a 10-year period. Scand J Plast Reconstr Surg 11
Suppl 16: 1-132.
2. Brånemark, P.-I. 1983. Osseointegration and its experimental background. J Prosthet Dent 50:
399-410.
3. Williams, D.F. 2001. Titanium for medical applications. In Brunette, D.M., Tengvall, P., Textor,
M., and Thomsen, P. (eds.), Titanium in Medicine, pp. 13-24, Berlin: Springer.
4. Niinomi, M. 2003. Recent research and development in titanium alloys for biomedical applica-
tions and healthcare goods. Sci Technol Adv Mat 4: 445-454.
5. Narushima, T. 2008. Surface modification for improving biocompatibility of titanium materials
with bone. J Jpn Inst Light Metals 58: 577-582.
6. LeGeros, R.Z. 1988. Calcium phosphate materials in restorative dentistry: a review. Adv Dent
Res 2: 164-180.
7. Yankee, S.J., Pletka, B.J., Salsbury, R.L., and Johnson, W.A. 1991. Historical development of
plasma sprayed hydroxylapatite biomedical coatings. In Sudarshan, T.S., Bhat, D.G., and
Jeandin, M. (eds.), Surface Modification Technologies IV , pp. 261-270, Warrendale, PA: TMS.
8. de Groot, K., Geesink, R., Klein, C.P.A.T., and Serekian, P. 1987. Plasma sprayed coatings of
hydroxylapatite. J Biomed Mater Res 21: 1375-1381.
9. Yang, Y., Kim, K.H., and Ong, J.L. 2005. A review on calcium phosphate coatings produced
using a sputtering process—An alternative to plasma spraying. Biomaterials 26: 327-337.
10. Nimmagadda, R. and Bunshah, R.F. 1971. Temperature and thickness distribution on substrate
during high-rate physical vapor-deposition of materials. J Vac Sci Technol 8: VM85-VM94.
11. Narushima, T. 2007. Surface morphology and composition/phase control in metallic biomateri-
als. J Jpn Soc Biomater 25: 252-260.
12. Lee, I.-S., Whang, C.-N., Kim, H.-E., Park, J.-C., Song, J.H., and Kim, S.-R. 2002. Various Ca/P
ratios of thin calcium phosphate films. Mater Sci Eng C 22: 15-20.
13. Wolke, J.C.G., van Dijk, K., Schaeken, H.G., de Groot, K., and Jansen, J.A. 1994. Study of the
surface characteristics of magnetron-sputter calcium phosphate coatings. J Biomed Mater Res 28:
1477-1484.
14. Yoshinari, M., Hayakawa, T., Wolke, J.G.C., Nemoto, K., and Jansen, J.A. 1997. Influence of
rapid heating with infrared radiation on RF magnetron-sputtered calcium phosphate coatings.
J Biomed Mater Res 37: 60-67.
 
Search WWH ::




Custom Search