Biomedical Engineering Reference
In-Depth Information
33. Jacobs JJ, Gilbert JL, Urban RM (1998) Corrosion of metal orthopaedic implants. J Bone Joint
Surg Am 80:268-282
34. Jacobs JJ, Hallab NJ, Skipor AK, Urban RM (2003) Metal degradation products: a cause for
concern in metal-metal bearings? Clin Orthop Relat Res (417):139-147
35. Jacobs JJ, Silverton C, Hallab NJ, Skipor AK, Patterson L, Black J, Galante JO (1999) Metal
release and excretion from cementless titanium alloy total knee replacements. Clin Orthop
Relat Res (358):173-180
36. Jacobs JJ, Skipor AK, Black J, Urban R, Galante JO (1991) Release and excretion of metal in
patients who have a total hip-replacement component made of titanium-base alloy. J Bone
Joint Surg Am 73:1475-1486
37. Jacobs JJ, Skipor AK, Patterson LM, Hallab NJ, Paprosky WG, Black J, Galante JO (1998)
Metal release in patients who have had a primary total hip arthroplasty. A prospective con-
trolled longitudinal study. J Bone Joint Surg Am 80:1447-1458
38. Jefferies H, Coster J, Khalil A, Bot J, Mccauley RD, Hall JC (2003) Glutathione. ANZ J Surg
73:517-522
39. Kalbacova M, Roessler S, Hempel U, Tsaryk R, Peters K, Scharnweber D, Kirkpatrick JC,
Dieter P (2007) The effect of electrochemically simulated titanium cathodic corrosion prod-
ucts on ROS production and metabolic activity of osteoblasts and monocytes/macrophages.
Biomaterials 28:3263-3272
40. Kinov P, Leithner A, Radl R, Bodo K, Khoschsorur GA, Schauenstein K, Windhager R (2006)
Role of free radicals in aseptic loosening of hip arthroplasty. J Orthop Res 24:55-62
41. Konttinen YT, Zhao D, Beklen A, Ma G, Takagi M, Kivela-Rajamaki M, Ashammakhi N,
Santavirta S (2005) The microenvironment around total hip replacement prostheses. Clin
Orthop Relat Res (430):28-38
42. Kuwabara K, Ogawa S, Matsumoto M, Koga S, Clauss M, Pinsky DJ, Lyn P, Leavy J, Witte L,
Joseph-Silverstein J, Al E (1995) Hypoxia-mediated induction of acidic/basic fibroblast growth
factor and platelet-derived growth factor in mononuclear phagocytes stimulates growth of
hypoxic endothelial cells. Proc Natl Acad Sci U S A 92:4606-4610
43. Larsson J, Persson C, Tengvall P, Lundqvist-Gustafsson H (2004) Anti-inflammatory effects of
a titanium-peroxy gel: role of oxygen metabolites and apoptosis. J Biomed Mater Res A
68:448-457
44. Lee MC, Yoshino F, Shoji H, Takahashi S, Todoki K, Shimada S, Kuse-Barouch K (2005)
Characterization by electron spin resonance spectroscopy of reactive oxygen species generated
by titanium dioxide and hydrogen peroxide. J Dent Res 84:178-182
45. Lee SR, Kwon KS, Kim SR, Rhee SG (1998) Reversible inactivation of protein-tyrosine
phosphatase 1B in A431 cells stimulated with epidermal growth factor. J Biol Chem 273:
15366-15372
46. Lee TM, Chang E, Yang CY (2000) A comparison of the surface characteristics and ion release
of Ti 6 Al 4 V and heat-treated Ti 6 Al 4 V. J Biomed Mater Res 50:499-511
47. Ley K, Laudanna C, Cybulsky MI, Nourshargh S (2007) Getting to the site of inflammation:
the leukocyte adhesion cascade updated. Nat Rev Immunol 7:678-689
48. Li J, Zhang YP, Kirsner RS (2003) Angiogenesis in wound repair: angiogenic growth factors
and the extracellular matrix. Microsc Res Tech 60:107-114
49. Lin HY, Bumgardner JD (2004) In vitro biocorrosion of Ti-6Al-4V implant alloy by a mouse
macrophage cell line. J Biomed Mater Res A 68:717-724
50. Long M, Rack HJ (1998) Titanium alloys in total joint replacement-a materials science per-
spective. Biomaterials 19:1621-1639
51. Lu SC (2000) Regulation of glutathione synthesis. Curr Top Cell Regul 36:95-116
52. Lum H, Roebuck KA (2001) Oxidant stress and endothelial cell dysfunction. Am J Physiol
Cell Physiol 280:C719-C741
53. Macdonald SJ (2004) Metal-on-metal total hip arthroplasty: the concerns. Clin Orthop Relat
Res (429):86-93
Search WWH ::




Custom Search