Biomedical Engineering Reference
In-Depth Information
59. Perez MA, Fornell P, Garcia-Aznar JM, Doblaret M (2007) Validation of bone remodelling
models applied to different bone types using Mimics. Available online at: www.materialise.
com/download/
60. DeCoster TA, Heetderks DB, Downey DJ, Ferries JS, Jones W (1990) Optimizing bone screw
pullout force. J Orthop Trauma 4:169-174
61. Costi JJ, Kelly AJ, Hearn TC, Martin DK (2001) Comparison of torsional strengths of
bioabsorbable screws for anterior cruciate ligament reconstruction. Am J Sports Med
29:575-580
62. Buelow JU, Siebold R, Ellermann A (2002) A prospective evaluation of tunnel enlargement in
anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical
fixation. Knee Surg Sports Traumatol Arthrosc 10:80-85
63. Koranyi E, Bowman E, Knecht CD, Jansen M (1970) Holding power of orthopaedic screws in
bone. Clin Orthop 72:283-286
64. Wang Y, Mori R, Ozoe N, Nakai T, Uchio Y (2009) Proximal half angle of the screw thread is
a critical design variable affecting the pull-out strength of cancellous bone screws. Clin
Biomech 24(9):781-785
65. Black KP, Saunders MM, Stube KC, Moulton MJ, Jacobs CR (2000) Effects of interference
fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am
J Sports Med 28:846-849
66. Lima SA, Cha JY, Hwang CJ (2008) Insertion torque of orthodontic miniscrews according to
changes in shape, diameter and length. Angle Orthod 78:234-240
67. Selby JB, Johnson DL, Hester P, Caborn DN (2001) Effect of screw length on bioabsorbable
interference screw fixation in a tibial bone tunnel. Am J Sports Med 29:614-619
68. Schatzker J, Sanderson R, Murnaghan JP (1975) The holding power of orthopaedic screws
in vivo. Clin Orthop 108:115-122
69. Rubel I, Fornari E, Miller B, Hayes W (2006) Are self tapping screw similar? A biomechanical
study. J Bone Joint Surg Br 88-B:30
70. Bucholz RW, Jones A (1991) Fractures of the shaft of the femur. J Bone Joint Surg Am
73:1561
71. Gausepohl T, Möhring R, Pennig D, Koebke J (2001) Fine thread versus coarse thread.
A comparison of the maximum holding power. Injury 32:1-7
72. Lavi A (2010) Internal fixation using cannulated screws. Technical paper available online:
http://www.vilex.com/html/products/technical_training/internal_ fi xation_paper.html
73. Hoffmann R, Weiler A, Helling HJ, Ktek C, Rehm KE (1997) Local foreign-body reactions to
biodegradable implants. A classification. Unfallchirg 100:658-666
74. Harrington IJ (1976) A bioengineering analysis of force actions at the knee in normal and
pathological gait. Biomed Eng 11:167-172
75. Törmälä P (1992) Biodegradable self-reinforced composite materials: manufacturing structure
and mechanical properties. Clin Mater 10:29-34
76. http://www.qmed.com/mpmn/medtechpulse/fraunhofer-implant-material-promotes-bone-
growth
77. Zhou W (2010) Selective laser sintering of poly(L-lactide)/carbonated hydroxyapatite porous
scaffolds for bone tissue engineering, Tissue Engineering, Chapter 9. University of Hong
Kong, Hong Kong, pp 179-204. ISBN 978-953-307-079-7
78. Williams JM, Adewunmi A, Schek RM, Flanagann CL, Krebsbach PH, Feinberg SE, Hollister
SJ, Das S (2005) Bone tissue engineering using polycaprolactone scaffolds fabricated via
selective laser sintering. Biomaterials 26(23):4817-4827
Search WWH ::