Biomedical Engineering Reference
In-Depth Information
36. Abshire BB, McLain RF, Valdevit A, Kambic HE (2001) Characteristics of pullout failure in
conical and cylindrical pedicle screws after full insertion and backout. Spine J 1:408-414
37. Asnis SE, Ernberg JJ, Bostrom MP, Wright TM, Harrington RM, Tencer A, Peterson M (1996)
Cancellous bone screw thread design and holding power. J Orthop Trauma 10:462-469
38. Battula S, Schoenfeld A, Vrabec G, Njus GO (2006) Experimental evaluation of the holding
power/stiffness of the self-tapping bone screws in normal and osteoporotic bone material. Clin
Biomech 2:533-537
39. Brown GA, McCarthy T, Bourgeault CA, Callahan DJ (2000) Mechanical performance of
standard and cannulated 4.0-mm cancellous bone screws. J Orthop Res 18:307-312
40. Chapman JR, Harrington RM, Lee KM, Anderson PA, Tencer AF, Kowalski D (1996) Factors
affecting the pullout strength of cancellous bone screws. J Biomech Eng 118:391-398
41. Chizari M, Wang B, Snow M (2007) Experimental and numerical analysis of screw fixation in
anterior cruciate ligament reconstruction. Proceedings of the World Congress on Engineering,
London, UK
42. Herrera A, Martínez F, Iglesias D, Cegońino J, Ibarz E, Gracia L (2010) Fixation strength of
biocomposite wedge interference screw in ACL reconstruction: effect of screw length and
tunnel/screw ratio. A controlled laboratory study. BMC Musculoskelet Disord 11:139-146
43. Kissel CG, Friedersdorf SC, Foltz DS, Snoeyink T (2003) Comparison of pullout strength of
small-diameter cannulated and solid-core screws. J Foot Ankle Surg 42:334-338
44. Mann CJ, Costi JJ, Stanley RM, Dobson PJ (2005) The effect of screw taper on interference fit
during load to failure at the soft tissue/bone interface. Knee 12:370-376
45. Patel PS, Shepherd DE, Hukins DW (2010) The effect of screw insertion angle and thread type
on the pullout strength of bone screws in normal and osteoporotic cancellous bone models.
Med Eng Phys 32:822-828
46. Ricci WM, Tornetta P 3rd, Petteys T, Gerlach D, Cartner J, Walker Z, Russell TA (2010)
A comparison of screw insertion torque and pullout strength. J Orthop Trauma 24:374-378
47. Yerby S, Scott CC, Evans NJ, Messing KL, Carter DR (2001) Effect of cutting flute design on
cortical bone screw insertion torque and pullout strength. J Orthop Trauma 15:216-221
48. Weiler A, Hoffman RFG, Siepe CJ, Kolbeck SF, Südkamp NP (2000) The influence of screw
geometry on hamstring tendon interference fit fixation. Am J Sports Med 28:356-359
49. Weiler A, Hoffmann RF, Stähelin AC, Bail HJ, Siepe CJ, Südkamp NP (1998) Hamstring
tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy
14:29-37
50. Hansson S, Werke M (2003) The implant thread as a retention element in cortical bone: the
effect of thread size and thread profile: a finite element study. J Biomech 36:1247-1258
51. Hou SM, Hsu CC, Wang JL, Chao CK, Lin J (2004) Mechanical tests and finite element mod-
els for bone holding power of tibial locking screws. Clin Biomech 19:738-745
52. Hsu CC, Chao CK, Wang JL, Hou SM, Tsai YT, Lin J (2006) Multiobjective optimization of
tibial locking screw design using a genetic algorithm: evaluation of mechanical performance.
J Orthop Res 24:908-916
53. Ashman RB, Rho JY, Turner CH (1989) Anatomical variation of orthotropic elastic moduli of
the proximal human tibia. J Biomech 22:895-900
54. Choi K, Kuhn JL, Ciarelli MJ, Goldstein SA (1990) The elastic moduli of human suchondral,
trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus.
J Biomech 23:1103-1113
55. Standard handbook of biomedical engineering and design (2003) In: Kutz M (ed) Bone
mechanics, Chapter 8. McGraw-Hill, New York, pp 1-23
56. Williams JL, Lewis JL (1982) Properties and an anisotropic model of cancellous bone from the
proximal tibial epiphysis. J Biomech Eng 104:50-56
57. Bessho M, Ohnishi I, Matsuyama J, Imai K, Nakamura K (2007) Prediction of strength and
strain of the proximal femur by a CT based finite element method. J Biomech 40:1745-1753
58. Jovanović JD, Jovanović ML (2010) Finite element modeling of the vertebra with geometry
and material properties retrieve from CT-scan data. Facta Universitatis: Mech Eng 8:19-26
Search WWH ::




Custom Search