Biomedical Engineering Reference
In-Depth Information
Biocomposite interference screws are commonly used now in the knee surgery.
Initial fixation strength and ease of insertion are vital to the stability of the recon-
struction of ACL, especially with soft tissue grafts and in the tibial tunnel.
In our study several new design features of an innovative interference screw were
proposed in order to ameliorate press-fit fixation without damaging the graft. We
proposed a self-tapping screw with conical shape and three cutting flutes at the dis-
tal end and cylindrical shape at the proximal end. The thread is different for these
two zones, more aggressive at the conical zone to easily penetrate the cortical bone,
while on the cylindrical zone the attack angle of the thread is bigger in order not to
damage the graft. Screw design optimization was made by changing the values of
the attack angles of the screw thread shapes and by determining different values of
the pullout force using finite element analysis.
However, as already mentioned, it is the combination between the design and
material which guarantees the integrity of the screw during insertion, the tissue
regrowth, and the stability of fi xation.
References
1. Bach BR Jr, Jones GT, Sweet FA, Hager CA (1994) Arthroscopy-assisted anterior cruciate
ligament reconstruction using patellar tendon substitution. Two to four-year follow-up results.
Am J Sports Med 22:758-767
2. Kurosaka M, Yoshiya S, Andrish JT (1987) A biomechanical comparison of different surgical
techniques of graft fixation in anterior cruciate ligament reconstruction. Am J Sports Med
15:225-229
3. Lambert KL (1983) Vascularized patellar tendon graft with rigid internal fixation for anterior
cruciate ligament insufficiency. Clin Orthop 172:85-89
4. Kurzweil PR, Frogameni AD, Jackson DW (1995) Tibial interference screw removal following
anterior cruciate ligament reconstruction. Arthroscopy 11:289-291
5. Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw.
A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268-271
6. Caborn DNM, Coen M, Neef R, Hamilton D, Nyland J, Johnson DL (1998) Quadrupled sem-
itendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and
a bioabsorbable interference screw. Arthroscopy 14:241-245
7. Caborn DNM, Urban WP Jr, Johnson DL, Nyland J, Pienkowski D (1997) Biomechanical
comparison between BioScrew and titanium alloy interference screws for bone-patellar
tendon-bone graft fixation in anterior cruciate ligament reconstruction. Arthroscopy 13:229-232
8. Johnson LL, van Dyk GE (1996) Metal and biodegradable interference screws: comparison of
failure strength. Arthroscopy 12:452-456
9. Kaeding C, Farr J, Kavanaugh T, Pedroza A (2005) A prospective randomized comparison of
bioabsorbable and titanium anterior cruciate ligament interference screws. Arthroscopy
21:147-151
10. Marti C, Imhoff AB, Bahrs C, Romero J (1997) Metallic versus bioabsorbable interference
screws for fixation of bone-patellar tendon-bone autograft in arthroscopic anterior cruciate liga-
ment reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc 5:217-221
11. Pena F, Grøntvedt T, Brown GA, Aune AK, Engebretsen L (1996) Comparison of failure
strength between metallic and absorbable interference screws. Influence of insertion torque,
tunnel-bone block gap, bone mineral density, and interference. Am J Sports Med 24:329-334
12. Walton M (1999) Absorbable and metal interference screws: comparison of graft security
during healing. Arthroscopy 15:818-826
Search WWH ::