Chemistry Reference
In-Depth Information
Table 1 Summary of sample studies for atmospheric nanoparticles in European countries
Country
Study location
Study year
Size range (nm)
Instrument
Reference
Roadside environments
UK
Cambridge
2007
10-2,500
DMS500
Kumar et al. [
79
]
UK
Manchester
2001
4-100
SMPS
Longley et al. [
105
]
UK
Leicester
2005
5-1,000
DMS500
Agus et al. [
106
]
UK
Birmingham
1996-1997
10-352
SMPS
Shi et al. [
107
]
UK
London
2009
7-1,000
CPC
Reche et al. [
93
]
Belgium
Antwerp
2009
20-500
TSI Monitor 3031
Can et al. [
108
]
Germany
Essen
2008
20-750
CPC-SMPS
Weber [
109
]
Germany
Leipzig
2003-2004
3-800
TDMPS
Voigtlander et al. [
110
]
Finland
Lahti
1995
6-300
UCPC
Vakeva et al. [
42
]
Finland
Helsinki
2002-2004
7-3,000
CPC
Puustinen et al. [
111
]
Greece
Athens
2002-2004
7-3,000
CPC
Puustinen et al. [
111
]
Netherlands
Amsterdam
2002-2004
7-3,000
CPC
Puustinen et al. [
111
]
Netherlands
Utrecht
2008
10+
CPC
Boogaard et al. [
112
]
Spain
Barcelona
2001
10+
CPC (3022A, TSI)
Paatero et al. [
113
]
Italy
Rome
2001
10+
CPC (3022A, TSI)
Paatero et al. [
113
]
France
Strasbourg
2003
7-10,000
ELPI
Roth et al. [
114
]
Denmark
Copenhagen
2007
6-700
DMPS
W˚hlin [
94
]
Czech Republic
Prague
2008
25-2,500
SMPS + APS
Ondr´cek et al. [
115
]
Austria
Vienna
2002-2003
7+
CPC
Gomiscek et al. [
116
]
Austria
Linz
2002-2003
7+
CPC
Gomiscek et al. [
116
]
Austria
Graz
2002-2003
7+
CPC
Gomiscek et al. [
116
]
Austria
Salzburg (Rudolfsplatz)
1998
13-830
SMPS
Morawska et al. [
117
]
Switzerland
Zurich
2001-2002
3+
SMPS + CPC + OPC
Bukowiecki et al. [
118
]
(continued)