Civil Engineering Reference
In-Depth Information
Location (Grid Lines)
Net Shears
6 from A to C
v = 100 + (14.4) = +114.4 plf
6 from C to E
v = 100 − (72.2) = +27.8 plf
7 (left) from A to C
v = +44.44 +(14.4) = +58.84 plf
7 (left) from C to E
v = +44.44 - (72.2) = −27.76 plf
7 (right) from A to C
= +53.33 plf
8 (left) from A to C
= 0 plf
8 (right) from A to B
v = 0 + (59.78) = +59.78 plf
8 (right) from B to C
v = 0 − (80.22) = −80.22 plf
8 (right) from C to E
v = 0 + (27.78)= +27.78 plf
9 (left) from A to B
v = −55.56 + (59.78) = +4.22 plf
9 (left) from B to C
v = −55.56 − (80.22) = −135.78 plf
9 (left) from C to E
v = −55.56 + (27.78) = −27.78 plf
9 (right) from A to B
= −125 plf
10 (left) from A to B
= −225 plf
Determination of longitudinal collector/chord forces (see Fig. 8.17):
F i g u r e 8.17 Longitudinal collector forces, diaphragm 2.