Geology Reference
In-Depth Information
Figure 23-3 Direct
Shear Apparatus [2]
Figure 23-4
Direct Shear
Apparatus
(1) The sample used for specimen preparation should be suffi-
ciently large so that a minimum of three similar specimens can be
prepared. Prepare the specimens in a controlled temperature and
humidity environment to minimize moisture loss or gain.
TEST
SPECIMEN [1]
(1.1) Extreme care should be taken in preparing undisturbed spec-
imens of sensitive soils to prevent disturbance to the natural
soil structure. Determine the initial mass of the wet specimen for