Table 5.1 Comparison of international dry storage regulations (Adamson et al ., 2011)
Dry storage
criteria
USA
Germany
Hungary
S. Korea
(CANDU only)
Spain (follows
USNRC)
Switzerland
Pellet clad ° C,
storage,
drying, other
400 ° 570 °
370 ° 370 ° , 100 hr
410 ° 410 °
None but
maintain
clad integrity
400 ° 570 °
None 570 °
Temperature
cycling
Max. no. of
cycles and
Max.
10/65 °
None
None
None
10/65 °
10/65 °
T ( ° C)
per cycle
Δ
BU, GWD/MT
None
65 assembly avg.
49 - 50
None
None
None
Clad hoop
stress, MPa
90 (if T clad >
400 ° C)
120@370 °
None
None
90
Depends on fuel
supplier*;
typical values
are 90 and
120
Clad strain
limit
None
1% circumferential
None
None
1% for HB
1% during
storage
Creep rupture
limits
None
None
None
None
Limited by ° T
and stress
limits
Cladding
condition
limits
Oxide
thickness
for stress
calculation
Oxide thickness
for stress
calculation
None
None
Limited by ° T
and stress
limits
None