Civil Engineering Reference
In-Depth Information
N
Ed
χ
y
N
Rk
/γ
M
1
<
C
my
1
+
0.8
=
0.90
200
×
10
3
0.693
×
47.2
×
10
2
×
275
/
1.0
×
1
+
0.8
×
=
1.060
TB.1
so that
k
yy
=
1.052
N
b
,
y
,
Rd
+
k
yy
M
y
,
Ed
N
Ed
M
c
,
y
,
Rd
=
200
900
+
1.052
×
45.0
132.8
=
0.222
+
0.356
=
0.579
<
1
6.3.3(4)
and the member resistance is adequate.
Beam-column member resistance - more exact approach (Annex A).
λ
max
=
λ
y
=
0.960
TA.1
N
cr
,
y
=
π
2
EI
y
/
L
cr
=
π
2
×
210000
×
5537
×
10
4
/
9000
2
=
1417kN.
Since there is no lateral buckling,
λ
0
=
0,
b
LT
=
0,
C
mLT
=
1.0
TA.1
C
my
=
C
my
,0
=
1
−
0.18
N
Ed
/
N
cr
,
y
=
1
−
0.18
×
200
/
1417
=
0.975 TA.2
w
y
=
W
pl
,
y
W
el
,
y
=
483
433
=
1.115,
200
×
10
3
47.2
×
10
2
×
275
/
1.0
=
0.154
N
Ed
N
Rk
/γ
M
1
=
n
pl
=
TA.1
2
−
1.6
w
y
C
my
λ
max
−
1.6
w
y
C
my
λ
2
C
yy
=
1
+
(
w
y
−
1
)
n
pl
−
b
LT
max
≥
W
el
,
y
W
pl
,
y
2
−
1.6
1.115
×
0.975
2
×
0.960
−
1.6
=
1
+
(
1.115
−
1
)
1.115
×
0.975
2
×
0.960
2
×
0.154
−
0
=
0.990
>
0.896
=
1
/
1.115
TA.1
Search WWH ::