Civil Engineering Reference
In-Depth Information
The resistance of the flanges to bending is
M f , Rd = ( 400 × 20 ) × ( 1540 20 ) × 345 / 1.0 Nmm
= 4195 kNm > 4000 kNm = M Ed
EC3-1-5 5.4(1)
and so the flange resistance is not completely utilised in resisting the bending
moment.
2 × ( 15 ε t f ) + t w = 2 × ( 15 × 0.814 × 20 ) + 10 = 498 mm > 400 mm
EC3-1-5 5.4(1)
b f = 400 mm < 498 mm
EC3-1-5 5.4(1)
0.25 + 1.6 × 400 × 20 2 × 345
10 × 1500 2 × 355
c = 1800 ×
= 469.9 mm
EC3-1-5 5.4(1)
2
4000
4195
V bf , Rd = 400 × 20 2 × 355
469.9 × 1.0
×
1
N = 11 kN
EC3-1-5 5.4(1)
V bw , Rd + V bf , Rd = 1733 + 11 = 1744 kN.
EC3-1-5 5.2(1)
4.10 Unworked examples
4.10.1 Example 12 - elastic local buckling of a beam
DeterminetheelasticlocalbucklingmomentforthebeamshowninFigure4.32a.
4.10.2 Example 13 - elastic local buckling of a beam-column
Determine the elastic local buckling load for the beam-column shown in
Figure 4.32b when M / N = 20 mm.
4.10.3 Example 14 - section capacity of a welded box beam
Determine the section moment resistance for the welded box beam of S275 steel
shown in Figure 4.32c.
4.10.4 Example 15- designing a plate web girder
The overall depth of the laterally supported plate girder of S275 steel shown in
Figure 4.32d must not exceed 1800 mm. Design a constant section girder for the
 
Search WWH ::