Civil Engineering Reference
In-Depth Information
Effective flange area.
k σ , f = 0.43
EC3-1-5T4.2
λ p , f = ( 400 / 2 10 / 2 8 )/ 10
28.4 × 0.814 × 0.43 = 1.23 > 0.748
EC3-1-5 4.4(2)
ρ f = ( 1.23 0.188 )/ 1.23 2 = 0.687
EC3-1-5 4.4(2)
A eff , f = 0.687 × 4 × ( 400 / 2 10 / 2 8 ) × 10
+ ( 10 + 2 × 8 ) × 10 × 2
EC3-1-5 4.4(1)
= 5658 mm 2
Effective web area.
k σ , w = 4.0
EC3-1-5T4.1
λ p , w = ( 420 2 × 10 2 × 8 )/ 10
28.4 × 0.814 ×
= 0.831 > 0.673
EC3-1-5 4.4(2)
4.0
ρ w ={ 0.831 0.055 × ( 3 + 1 ) } / 0.831 2 = 0.885
EC3-1-5 4.4(2)
A eff , w = 0.885 × ( 420 2 × 10 2 × 8 ) × ( 10 + 8 × 10 × 2 )
= 3558 mm 2
EC3-1-5 4.4(1)
Compression resistance.
A eff = 5658 + 3558 = 9216 mm 2
N c , Rd = 9216 × 355 / 1.0 N = 3272 kN.
4.9.2 Example 2 - section moment resistance of a
Class 3 I-beam
Problem. Determinethesectionmomentresistanceandexaminethesuitabilityfor
plastic design of the 356 × 171 UB 45 of S355 steel shown in Figure 4.31b.
Classifying the section-plate elements.
t f = 9.7 mm, t w = 7.0 mm, f y = 355 N / mm 2
EN10025-2
ε = ( 235 / 355 ) = 0.814
T5.2
c f /( t f ε) = ( 171.1 / 2 7.0 / 2 10.2 )/( 9.7 × 0.814 )
T5.2
= 9.1 > 9 but < 10, and so the flange is Class 2.
T5.2
c w /( t w ε) = ( 351.4 2 × 9.7 2 × 10.2 )/( 7.0 × 0.814 )
T5.2
= 54.7 < 72 and so the web is Class 1.
T5.2
Search WWH ::