Graphics Programs Reference
In-Depth Information
For air systems equipment, your duct connectors should be set with the
properties that coincide with the behavior of the equipment that the family
represents. Figure 19.21 shows the properties of a duct connector that has
just been added to a family.
FlowConfiguration The Flow Configuration parameter sets how the
flow is determined at the connector point, as shown in Figure 19.22 .
Calculated This option adds up all the flow values from objects
downstream in the system.
Preset This option is for direct input of the flow value at the
connector point.
System This option can be used if the flow at the connector point is
a percentage of the entire flow for a system. With the System option,
you will have to provide a value for the Flow Factor parameter. For
example, if the equipment you are creating is used in a system with
other equipment in your project and it provides 30 percent of the
flow, Flow Configuration would be set to System and Flow Factor
would be set to 0.33.
 
 
Search WWH ::




Custom Search