Graphics Programs Reference
In-Depth Information
Figure 10.24 Duct types
Note the default settings in the Properties palette for constraints,
including Justification, Reference Level, and Offset. The system type is
undefined, and because the duct is unconnected, the airflow is 0.
You can adjust additional properties from the Options Bar and the
Modify | Place Duct tab, shown in Figure 10.25 .
Figure 10.25 Duct settings
You can also inherit the elevation and size of existing connectors,
whether from ducts or families, when connecting to them. For round or
oval ducts, you can also choose the Ignore Slope To Connect option,
meaning that the duct will connect regardless of slope, or you can use
the specified angle.
2. The duct can then be created/drawn to whatever path you choose. For
vertical offsets, type the new height into the offset box on the Options
Bar. For an angled setup or set-down, it is best to work in an elevation
or sectional view.
 
 
 
Search WWH ::