Graphics Reference
In-Depth Information
Figure 20-2. Set the Motor Speed and Extrude Duration.
Next, set the Extruder temperature and test the thermocouple. Begin by setting the target
temperature (in Figure 20-3) to 100 C.
Figure 20-3. Set the target temperature and the current temperature will rise to match.
The control panel will show the current temperature and your target temperature. In the graph at
the bottom of the window shown in Figure 20-3, the current temperature is in red and the target
temperature is in blue.
 