Environmental Engineering Reference
In-Depth Information
to protect the evaporator from scaling. In order to find the number of arrays that need to be
taken out of service during April, the simulation program was run for different number of
arrays in operation. It was found that 4 arrays of the 76 arrays available need to be drained
making the available absorber area for this month 1,764 m 2 . The other operating conditions
are as given in table 17. These results translate into the optimum operating conditions shown
in table 19.
Table 18. Summary of simulation results for different heating water flow rates
H/W flow
m 3 /h
Production
m 3 /month
TME110
hrs
Month
Startups
Jan.
21
2360
11
28
19.5
2530
10
20
18
27600
0
11
16.5
2890
0
5
13.5
2830
0
4
12
2740
0
7
Feb.
21
3680
267
1
19.5
3710
207
0
18
3700
109
0
16.5
3680
68
0
15
3640
46
0
13.5
3600
23
0
12
3560
5
0
Mar.
21
3680
291
8
19.5
3860
233
2
18
3870
190
1
16.5
3850
126
1
15
3820
85
1
13.5
3780
41
1
12
3740
14
1
Apr.
21
4030
428
1
19.5
4050
385
0
18
4040
355
0
16.5
4010
317
0
15
3990
227
0
13.5
3950
140
0
12
3900
55
0
May
21
3940
224
3
19.5
3980
89
1
18
3950
53
1
16.5
3940
21
0
15
3910
2
0
13.5
3850
0
1
12
3830
0
0
Search WWH ::




Custom Search