Civil Engineering Reference
In-Depth Information
550 mm
550 mm
Joint J 2
U 1
U 2
450 mm
450 mm
D 2
Cover plate = 550 × 24
2 Web plate = 450 × 16
Lower flange plate = 400 × 24
V 2
400 mm
400 mm
Cover plate = 550 × 12
2 Web plate = 450 × 12
Lower flange plate = 400 × 12
400 mm
350 mm
350 mm
400 mm
2 Flange plate = 350 × 28
Web plate = 344 × 18
2 Flange plate = 350 × 32
Web plate = 336 × 22
550 mm
450 mm
R
= 20 mm
400 mm
10 mm thick
splice plate
Minimum 15°
400 mm
Figure 4.94 Details and drawings of the main truss joint J 2 .
4.3.3.37 Design of Joint J 3
Joint J 3 (see Figure 4.95 ) can be designed using the same M27 high-strength
pretensioned bolts as follows.
Number of Bolts for the Vertical Member V 3
N V ðÞ¼
7
103 ¼ 31 bolts, taken as 32 bolts (16 bolts in each side
acting in single shear)
F Ed
3190
:
F s , ult ¼
 
 
Search WWH ::