Table 3.23 Minimum and Maximum Spacing and End and Edge Distances Specified in EC3 (BS EN 1993-1-8) [2.13]
Distances and
Spacings
Minimum
Maximum
Structures Made from Steels Conforming to EN 10025 Except Steels
Conforming to EN 10025-5
Structures Made from Steels
Conforming to EN 10025-5
Steel exposed to the weather or
other corrosive influences
Steel not exposed to the weather or
other corrosive influences
Steel used unprotected
End distance
e
1
1.2
d
o
4
t
+40 mm
The larger of 8
t
or 125 mm
Edge distance
e
2
1.2
d
o
4
t
+40 mm
The larger of 8
t
or 125 mm
Distance
e
3
in
slotted holes
1.5
d
o
Distance
e
4
in
slotted holes
1.5
d
o
Spacing
p
1
2.2
d
o
The smaller of 14
t
or 200 mm The smaller of 14
t
or 200 mm
The smaller of 14
t
min
or
175 mm
Spacing
p
1,0
The smaller of 14
t
or 200 mm
Spacing
p
1,
i
The smaller of 28
t
or 400 mm
Spacing
p
2
2.4
d
o
The smaller of 14
t
or 200 mm The smaller of 14
t
or 200 mm
The smaller of 14
t
min
or
175 mm