Environmental Engineering Reference
In-Depth Information
Table 6. Test values of EIF of environment
Type Of EIF And Measurements Unit
Test Values of EIF
for Degrees of Test Hardness (see Table 5)
1
2
3
4
Air temperature (exposure time, h, not less):
low, not more
15°С (6 h)
15°С (6 h)
15°С (6 h)
15°С (6 h)
upper, not less
40°С (6 h)
50°С (6 h)
75°С (6 h)
150°С (10 h)
Rate of change, not less
5°С / h
10°С / h
20°С / h
Relative humidity (exposure time, h, not less):
low, at 15°С, not more
10% (24 h)
5% (24 h)
5% (24 h)
upper, at 30°С, not less
90% (72 h)
100% (72 h)
at 40°С, not less
90% (6 h)
at 50°С, not less
100% (6 h)
at 75°С, not less
100% (6 h)
at 150°С, not less
100% (6 h)
Barometric pressure
(exposure time, h, not less):
low, not more
50 кPа (24 h)
upper, not less
130 (5 h)
560 кPа (24 h)
0,3·10 -4 Gy / h 1,5·10 -4 Gy / h 9·10 -4 Gy / h 0,03 Gy / h*
3 Gy / h**
* Test value for products, located outside of technological boxes ** Test value for products, located inside of technological boxes Note.
Sign “-“means that tests are not executed
Absorbed dose rate of ionizing radiation,
not less
Table 7. Groups of location conditions
Sources
of Mechanical EIF
Group of Operation
Conditions
Mounting Technique
Group of Location
Conditions
Absent
Any
On building constructions
Р.1.1
On supporting constructions
Р.1.2
On technological equipment
Р.1.3
Available
Е.1.3, Е.1.4, Е.2.2
On building constructions
Р.2.1
On supporting constructions
Р.2.2
Е.1.1, Е.1.2, Е.2.1
On building constructions
Р.3.1
On supporting constructions
Р.3.2
On technological equipment
Р.3.3
Devices, participating in performance of
those functions that should be initiated and / or
performed during an earthquake (emergency reac-
tor shutdown, interlocking of driven mechanisms,
etc.) or directly after an earthquake (emergency
reactor cooling, residual heat removal, automatic
control of critical parameters, radiation environ-
ment control, etc.) relate to categories I earthquake
resistance. Device, related to category I earthquake
resistance, should be resistant to seismic EIF on a
place of its location, caused by an earthquake that
can occur on-site with a repeatability period of
 
Search WWH ::