Biomedical Engineering Reference
In-Depth Information
Carbone a, howie DW, mcgee m, Field J, pearcy m, Smith n, Jones E (2006), 'aging
performance of a compliant layer bearing acetabular prosthesis in an ovine hip
arthroplasty model', J Arthroplasty , 21 , 899-906. DOI: 10.1016/j.arth.2005.07.023.
Connelly Gm, rimnac Cm, Wright Tm, hertzberg rW, manson Ja (1984), 'Fatigue
crack propagation behavior of ultrahigh molecular weight polyethylene' J Orthop
Res , 2 , 119-125.
Costi J, Krishnan J, pearcy m (1998), 'Total wrist arthroplasty: a quantitative review of
the last 30 years'. J Rheumatol , 25 , 451-458.
Dowson D (2001), 'new joints for the millennium: wear control in total replacement
hip joints', Proc Inst Mech Eng H , 215 , 335-358.
Dowson D, Fisher J, Jin Zm, auger DD, Jobbins B (1991), 'Design considerations
for cushion form bearings in artificial hip joints', Proc Inst Mech Eng H , 205 ,
59-68.
Engh Ga, Zimmerman rL, parks nL, Engh Ca (2009), 'analysis of wear in retrieved
mobile and fixed bearing knee inserts', J Arthroplasty , 24 , 28-32, DOI: 10.1016/
j.arth.2009.03.010.
Estok Dm, Burroughs Br, muratoglu OK, harris Wh (2007), 'Comparison of hip simulator
wear of 2 different highly cross-linked ultra high molecular weight polyethylene
acetabular components using both 32-and 38-mm femoral heads', J Arthroplasty , 22 ,
581-589, DOI: 10.1016/j.arth.2006.07.009.
Fisher J (1994), 'Wear of ultra high molecular weight polyethylene in total artificial
joints', Curr Orthop , 8 , 164-169.
Fisher J, Dowson D (1991), 'Tribology of total artificial joints', Proc Inst Mech
Eng H , 205 , 73-79.
Fisher J, Jennings Lm, Galvin aL, Jin Zmm, Stone mh, Ingham E (2010), '2009 Knee
Society presidential guest lecture polyethylene wear in total knees', Clin Orthop Relat
Res , 468 , 12-18, DOI: 10.1007/s11999-009-1033-1.
Flannery m, mcGloughlin T, Jones E, Birkinshaw C (2008), 'analysis of wear and
friction of total knee replacements. part I. Wear assessment on a three station wear
simulator', Wear , 265 , 999-1008, DOI: 10.1016/j.wear.2008.02.024.
Galvin a, Kang L, Tipper J, Stone m, Ingham E, Jin Zm, Fisher J (2006), 'Wear of
crosslinked polyethylene under different tribological conditions', J Mater Sci Mater
Med , 17 , 235-243, DOI: 10.1007/s10856-006-7309-z.
Gill hS, Waite JC, Short a, Kellett CF, price aJ, murray DW (2006), ' In vivo measurement
of volumetric wear of a total knee replacement', Knee , 13 , 312-317, DOI: 10.1016/
j.knee.2006.04.001.
Glyn-Jones S, Saac S, Hauptfleisch J, McLardy-Smith P, Murray DW, Singh H (2008),
'Does highly cross-linked polyethylene wear less than conventional polyethylene in total
hip arthroplasty?', J Arthroplasty , 23 : 337-343, DOI: 10.1016/j.arth.2006.12.117.
Goldsmith aaJ, Dowson D (1999a), 'Development of a ten-station, multi-axis hip joint
simulator', Proc Inst Mech Eng H , 213 , 311-316.
Goldsmith aaJ, Dowson D (1999b), 'a multi-station hip joint simulator study of the
performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene
total replacement hip joints', Proc Inst Mech Eng H , 213 , 77-90.
Gomez-Barrena E, puertolas Ja, munuera L, Konttinen YT (2008), 'Update on
UhmWpE research: from the bench to the bedside' Acta Orthop , 79, 832-40,
DOI: 10.1080/17453670810016939.
hall rm, Unsworth a, Siney p, Wroblewski Bm (1996), 'Wear in retrieved Charnley
acetabular sockets', Proc Inst Mech Eng H , 210 , 197-207.
￿ ￿ ￿ ￿ ￿ ￿
Search WWH ::




Custom Search