Environmental Engineering Reference
In-Depth Information
Fig. 13.5 Photograph of the
structural model installed at
the DTU laboratory. Overall
view (a), lateral (b) and front
(c) view of the base
3. No. 2 data acquisition boards National Instruments PXI-6259, multi-function
high-speed, optimized for high accuracies and speed of acquisition (up to
2,800 kHz), 8-channel analog inputs, 4 analog outputs (in the range ±10 V),
16 bits of resolution;
4. No. 1 digital multimeter National Instruments PXI-4065, 6 -digit for high
speed measuring of voltage, current and resistance;
5. No. 2 connector blocks National Instruments BNC-2110;
6. No. 1 voltage attenuator module (10 to 1) National Instruments SCC-A10, dual
channel, with voltage inputs up to ±60 V (''C'' in Fig. 13.6 );
7. No. 1 capacitance of 1.0 lF needed to stabilize the current loop (''A'' in
Fig. 13.6 );
8. The software environment NI Labview Professional Development System
(''B'' in Fig. 13.6 );
9. Real time operating system labview by NI for testing in real time;
10. No. 1 chassis national instruments able to host components 2, 3, 4 (''D'' in
Fig. 13.6 ).